Engineering Development of a Bi-directional Arterial Cannula with Peripheral Access for Cardiopulmonary Bypass
Cardiovascular Engineering and Technology · 2026
DOI: 10.1007/s13239-026-00820-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cardiovascular Engineering and Technology, 2026. Verfasst von Joel D Graham und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, University of Louisville, Louisville, KY, USA. joel.graham@louisville.edu. Hauptthemen laut MEDLINE: Cardiopulmonary Bypass, Cannula, Catheterization, Peripheral, Vascular Access Devices. Die Arbeit nennt 20 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Cardiopulmonary bypass (CPB) is a well-established procedure that uses cannulae during cardiac surgery to drain and return blood. In challenging cases (e.g. aortic dissection, reoperation), peripheral cannulation in vessels such as the axillary artery are used. However, standard cannulae at these sites may inhibit blood flow to distal extremities or require grafts that increase surgical time. This study evaluates a novel, flexible-tip arterial cannula designed for bi-directional flow. METHODS: A 22Fr body cannula was developed to achieve a pressure loss (ΔP) < 100 mmHg and 80/20 bi-directional flow distribution between tip outlets. A full factorial design of experiments (2-levels, 4 factors: tip A-width, B-height, C-depth, D-outlet shape) was completed to evaluate sixteen cannula tip designs using benchtop hydraulic and bi-directional flow models. Prototypes were fabricated using 3D printing via stereolithography (Form 3 + , Formlabs, Somerville, MA) with a flexible (50A) cured resin. RESULTS: The most efficient cannula design (A - , B + , C + , D + ) achieved 4 L/min of total bi-directional flow at a ΔP of 74 mmHg. The average ΔP at 4 L/min for all candidate design was 87 ± 9 mmHg (range 72-100 mmHg). Primary outlet flow distribution averaged 81% ± 6% (range 70-95%) at 1-5 L/min flow rates. Tip width had the greatest influence on ΔP, followed by outlet shape, depth, and their interactions, respectively. Cylindrical and prolate spheroid shaped tips outperformed spherical designs. CONCLUSION: The novel cannula demonstrated feasibility and proof-of-concept as evidenced by bi-directional flow with ΔP comparable to commercial cannulae. Future work will involve CFD modeling and pre-clinical validation (e.g. hemolysis, cadaver fit) to support development of a low-cost, clinical grade bi-directional flow cannula for peripheral CPB to reduce surgical complexity and lower risk of adverse events.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Bioengineering, University of Louisville, Louisville, KY, USA. joel.graham@louisville.edu.
- Department of Bioengineering, University of Louisville, Louisville, KY, USA.
- Department of Cardiovascular and Thoracic Surgery, University of Louisville, 302 E. Muhammad Ali Blvd, room 411, Louisville, KY, USA.
ORCID-Profile: Joel D Graham, Thomas J Roussel, Steven C Koenig, Mark S Slaughter
Zitieren
APA
Graham, J. D., Roussel, T. J., Koenig, S. C., & Slaughter, M. S. (2026). Engineering Development of a Bi-directional Arterial Cannula with Peripheral Access for Cardiopulmonary Bypass. Cardiovascular Engineering and Technology. https://doi.org/10.1007/s13239-026-00820-6
Vancouver
Graham JD, Roussel TJ, Koenig SC, Slaughter MS. Engineering Development of a Bi-directional Arterial Cannula with Peripheral Access for Cardiopulmonary Bypass. Cardiovascular Engineering and Technology. 2026. doi:10.1007/s13239-026-00820-6
BibTeX
@article{Graham2026,
author = {Graham, Joel D and Roussel, Thomas J and Koenig, Steven C and Slaughter, Mark S},
title = {Engineering Development of a Bi-directional Arterial Cannula with Peripheral Access for Cardiopulmonary Bypass},
journal = {Cardiovascular Engineering and Technology},
year = {2026},
doi = {10.1007/s13239-026-00820-6}
}
EUVIMED