A multicentre prospective assessment of the utility of robotic assisted total hip arthroplasty with virtual range of motion on intraoperative implant positioning
HIP International · 2024
DOI: 10.1177/11207000241254353 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift HIP International, 2024. Verfasst von Scott M LaValva und 6 weiteren Autor:innen. Beteiligte Einrichtung: Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY, USA. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Range of Motion, Articular, Robotic Surgical Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: stryker.
Abstract (Originalsprache)
Background
The growing adoption of robotic-assistance during total hip arthroplasty (THA) has provided novel means through which a patient’s anatomy and dynamic spinopelvic relationship can be incorporated into surgical planning. However, the impact of enhanced technologies on intraoperative decision-making and changes to component positioning has not yet been described.
Methods
A multicentre, prospective study included 105 patients (52% women) patients who underwent robotic-assisted THA with the integration of software that incorporates a patient’s pelvic tilt (PT) and virtual range-of-motion (VROM) for impingement modeling. The primary outcome of the study was the percentage of patients who underwent changes to the preoperative plan for cup position after incorporating the data from the software.
Results
Utilising the intraoperative VROM information, the preoperative plan for cup position was changed from the default (40° inclination and 20° anteversion) in 82/105 (78%) cases. When stratifying by spinopelvic mobility, 64% were considered normal (change ⩾ 10° and ⩽30°), 27% were stiff (change < 10°), and 9% were hypermobile (change > 30°). For all cohorts, the majority of cases (78%) deviated from the 40° inclination and 20° version target. When evaluating the proportion of cases within the Lewinnek and Callanan safe zones based on spinopelvic mobility, 19% of cases within the normal group were planned outside of both zones compared to 39% of stiff cases and 10% of hypermobile cases.
Conclusions
Utilising the latest version of robotic-assisted THA software, the preoperative plan for cup position was changed in the vast majority (78%) of patients, causing substantial deviations from traditional, generic cup targets.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY, USA.
- South County Orthopaedics, Ortho Rhode Island, Wakefield, RI, USA.
- American Hip Institute, Des Plaines, IL, USA.
Förderung
- stryker
Zitieren
APA
LaValva, S. M., Westrich, G. H., Marchand, R. C., Lall, A. C., Domb, B. G., Vigdorchik, J. M., & Jerabek, S. A. (2024). A multicentre prospective assessment of the utility of robotic assisted total hip arthroplasty with virtual range of motion on intraoperative implant positioning. HIP International. https://doi.org/10.1177/11207000241254353
Vancouver
LaValva SM, Westrich GH, Marchand RC, Lall AC, Domb BG, Vigdorchik JM, et al. A multicentre prospective assessment of the utility of robotic assisted total hip arthroplasty with virtual range of motion on intraoperative implant positioning. HIP International. 2024. doi:10.1177/11207000241254353
BibTeX
@article{LaValva2024,
author = {LaValva, Scott M and Westrich, Geoffrey H and Marchand, Robert C and Lall, Ajay C and Domb, Benjamin G and Vigdorchik, Jonathan M and Jerabek, Seth A},
title = {A multicentre prospective assessment of the utility of robotic assisted total hip arthroplasty with virtual range of motion on intraoperative implant positioning},
journal = {HIP International},
year = {2024},
doi = {10.1177/11207000241254353}
}
EUVIMED