EUVIMEDEUVIMED entdecken
Vergleichsstudie

Impact of Robotic Assistance on Total Hip Arthroplasty: Granular Insights Into Surgical Time

Karlos E Zepeda, Carmelo Burgio, Theofilos Karasavvidis, Tsion M Yared, Cale Pagan, Edward H Grabov, Seth A Jerabek, David J Mayman, Jonathan M Vigdorchik

The Journal of Arthroplasty · 2025

DOI: 10.1016/j.arth.2025.03.068 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Arthroplasty, 2025. Verfasst von Karlos E Zepeda und 8 weiteren Autor:innen. Beteiligte Einrichtung: Adult Reconstruction and Joint Replacement Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Robotic Surgical Procedures, Operative Time. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Hospitals need efficiency and cost-effectiveness due to the shift to a value-based health care system. While robotic-assisted total hip arthroplasty (RA-THA) provides improved accuracy of component positioning, surgeons are concerned about increased surgical times. This study compared surgical time between RA-THA and manual THA (M-THA) through a granular analysis of individual procedural steps. METHODS: This prospective study was conducted at a single institution from February to March 2024. A consecutive series of 50 primary posterior-approach THA cases were included, excluding patients who had prior hardware or previous ipsilateral surgery. The study comprised 25 RA-THAs and 25 M-THAs. There were six clinical fellows, supervised by five attending orthopaedic surgeons, who performed the surgeries, representing a typical clinical training scenario. Of the attending surgeons, three conducted RA-THAs using a computed tomography-based robotic platform, while two performed manual procedures. Key intraoperative steps individually recorded included pin placement, registration, and robotic reaming in the RA-THA group and acetabular reaming in the M-THA group. Multivariate regression models evaluated the impact of robotic assistance on surgical times. RESULTS: Total surgical times were similar for both groups (76 ± 10 versus 77 ± 13 minutes, P = 0.8). Robotic assistance did not significantly affect total surgical time (P = 0.5; 95% confidence interval: -8.7 to 19.7). The combined time for pin placement, registration, and reaming in RA-THA was comparable to acetabular reaming in M-THA (7 ± 1.1 versus 6.8 ± 1.8 minutes, P = 0.7). Acetabulum reaming in RA-THA was significantly shorter than in M-THA (2.3 ± 0.7 versus 6.8 ± 1.8 minutes, P < 0.001). Pin placement and registration times were 2.2 ± 0.9 and 2.4 ± 0.7 minutes, respectively. CONCLUSIONS: The use of RA-THA does not increase surgical time compared to M-THA, indicating that the use of robotic systems can maintain operative room efficiency. The additional time required for robotics seems to be offset by the reduced time needed for acetabular reaming. These findings support the broader adoption of robotic assistance in THA, offering potential benefits without compromising time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipRobotic Surgical ProceduresOperative TimeHumansProspective StudiesMaleFemaleMiddle AgedAged

Stichwörter der Autor:innen

operative timerobotic-assisted surgeryroboticstotal hip arthroplastytotal joint arthroplasty

Autor:innen und Institutionen

  • Adult Reconstruction and Joint Replacement Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York.
  • Adult Reconstruction and Joint Replacement Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York; Department of Orthopedic Surgery, Balgrist University Hospital, University of Züri…

Zitieren

APA

Zepeda, K. E., Burgio, C., Karasavvidis, T., Yared, T. M., Pagan, C., Grabov, E. H., Jerabek, S. A., Mayman, D. J., & Vigdorchik, J. M. (2025). Impact of Robotic Assistance on Total Hip Arthroplasty: Granular Insights Into Surgical Time. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2025.03.068

Vancouver

Zepeda KE, Burgio C, Karasavvidis T, Yared TM, Pagan C, Grabov EH, et al. Impact of Robotic Assistance on Total Hip Arthroplasty: Granular Insights Into Surgical Time. The Journal of Arthroplasty. 2025. doi:10.1016/j.arth.2025.03.068

BibTeX
@article{Zepeda2025,
  author = {Zepeda, Karlos E and Burgio, Carmelo and Karasavvidis, Theofilos and Yared, Tsion M and Pagan, Cale and Grabov, Edward H and Jerabek, Seth A and Mayman, David J and Vigdorchik, Jonathan M},
  title = {Impact of Robotic Assistance on Total Hip Arthroplasty: Granular Insights Into Surgical Time},
  journal = {The Journal of Arthroplasty},
  year = {2025},
  doi = {10.1016/j.arth.2025.03.068}
}
Kostenlos starten →