Beyond jump distance: modular dual mobility versus single mobility cups in robotic total hip arthroplasty - simulation of hip kinematics and impingement
International Orthopaedics · 2026
DOI: 10.1007/s00264-025-06731-w ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Orthopaedics, 2026. Verfasst von Pascal Kouyoumdjian und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Centre Hospitalier Universitaire de Nîmes, Nîmes, France. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Robotic Surgical Procedures, Hip Joint. Die Arbeit nennt 27 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Modular dual mobility (MDM) cups are widely used in primary total hip arthroplasty (THA) to reduce dislocation, but their impact on range of motion (ROM) to impingement versus single-mobility (SM) cups remains uncertain. METHODS: In this paired robotic-simulation study, 108 primary robotic-assisted THAs were virtually planned twice with CT-based software, once with an SM cup and once with an MDM cup. Cup and stem orientation were optimised to restore intra-articular length and global offset within 5 mm of the contralateral hip and to avoid impingement. ROM to first impingement was measured in extension/external rotation (ER), flexion/internal rotation (IR) with physiological pelvic tilt, and flexion/IR with 20° adduction. The mode of first impingement (intra-articular, extra-articular, or mixed) was recorded. RESULTS: Compared with SM, MDM cups increased ROM to impingement in extension and ER but slightly reduced ROM in flexion and IR at several test positions. Maximal extension to impingement and ER in extension were higher with MDM, whereas flexion with pelvic anteversion and IR at 100° flexion were lower. ROM to impingement was not uniformly greater with MDM, and first contact often shifted from intra-articular implant-on-implant impingement toward extra-articular impingement. CONCLUSION: In robotic THA, MDM cups provide selective gains in ROM to impingement and shift the impingement towards extra-articular structures rather than providing a global increase in safe ROM. Clinically, MDM may suit patients needing extension/ER reserve or with anterior instability risk, and planning should consider osteophytes and bony constraints. Further prospective clinical validation is warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Centre Hospitalier Universitaire de Nîmes, Nîmes, France.
- University Mechanical and Civil Engineering Laboratory UMR 5508 CNRS-UMCC 048, 163 rue Auguste Broussonnet, Montpellier, 34090, France.
- Department of Orthopedic Surgery, Lebanese American University Medical Center-Rizk Hospital, Beirut, Lebanon. youssefjd@outlook.com.
- Lebanese American University Medical Center-Rizk Hospital, Beirut, Lebanon.
Zitieren
APA
Kouyoumdjian, P., Jamaleddine, Y., Chapron, E., Haj Hussein, A., Al Suwaidi, M., & Coulomb, R. (2026). Beyond jump distance: modular dual mobility versus single mobility cups in robotic total hip arthroplasty - simulation of hip kinematics and impingement. International Orthopaedics. https://doi.org/10.1007/s00264-025-06731-w
Vancouver
Kouyoumdjian P, Jamaleddine Y, Chapron E, Haj Hussein A, Al Suwaidi M, Coulomb R. Beyond jump distance: modular dual mobility versus single mobility cups in robotic total hip arthroplasty - simulation of hip kinematics and impingement. International Orthopaedics. 2026. doi:10.1007/s00264-025-06731-w
BibTeX
@article{Kouyoumdjian2026,
author = {Kouyoumdjian, Pascal and Jamaleddine, Youssef and Chapron, Emeline and Haj Hussein, Ahmad and Al Suwaidi, Mohammad and Coulomb, Rémy},
title = {Beyond jump distance: modular dual mobility versus single mobility cups in robotic total hip arthroplasty - simulation of hip kinematics and impingement},
journal = {International Orthopaedics},
year = {2026},
doi = {10.1007/s00264-025-06731-w}
}
EUVIMED