Ten-Year Functional Outcomes Following Robotic-Assisted Total Hip Arthroplasty: A Case Series
The Journal of Arthroplasty · 2026
DOI: 10.1016/j.arth.2026.01.052 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2026. Verfasst von Benjamin G Domb und 5 weiteren Autor:innen. Beteiligte Einrichtung: American Hip Institute Research Foundation, Chicago, Illinois; American Hip Institute, Chicago, Illinois. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Joint, Robotic Surgical Procedures, Osteoarthritis, Hip. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Robotic-assisted total hip arthroplasty (rTHA) has been shown to assist with precision in component placement. However, limited evidence exists evaluating its effects on minimum 10-year clinical outcomes. The purpose of this study was to report the minimum 10-year clinical outcomes in a case series of patients who underwent rTHA. METHODS: Prospectively collected data from patients who underwent primary rTHA between June 2011 and April 2015 were analyzed. Patients who had a complete minimum 10-year follow-up, including radiographs and validated patient-reported outcomes, were included. A total of 215 hips met the inclusion criteria. The patient-reported outcomes included the Harris Hip Score, Hip Disability and Osteoarthritis Outcome Score-Joint Replacement, Forgotten Joint Score-12 (FJS-12), visual analog scale pain, and patient satisfaction. Radiographic assessment included acetabular cup inclination, version, leg-length discrepancy, and cup placement relative to the Lewinnek and Callanan safe zones. RESULTS: At the final follow-up, patients reported excellent outcomes, with mean Harris Hip Score 93.0 ± 12.6, Hip Disability and Osteoarthritis Outcome Score-Joint Replacement 89.1 ± 16.1, FJS-12 85.2 ± 22.4, visual analog scale pain 1.0 ± 1.9, and satisfaction 9.1 ± 1.8. The high FJS-12 score reflects that patients rarely or almost never thought about their hip in daily life. There were six revisions (2.8%): one for aseptic loosening (0.5%), one for leg-length discrepancy (0.5%), and four for acute postoperative infection (1.9%). Survivorship free of revision was 97.2% at 10 years. Radiographic analysis demonstrated that 91.1% of cups were within the Lewinnek safe zone and 87.4% within the Callanan safe zone. Notably, there were no cases of instability or dislocation. CONCLUSIONS: Robotic-assisted primary THA was associated with a high degree of accuracy in component placement and durable clinical outcomes with high patient satisfaction and low revision rates at a minimum 10-year follow-up. LEVEL OF EVIDENCE: Level IV.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- American Hip Institute Research Foundation, Chicago, Illinois; American Hip Institute, Chicago, Illinois.
- American Hip Institute Research Foundation, Chicago, Illinois.
- American Hip Institute Research Foundation, Chicago, Illinois; Department of Orthopaedic Surgery, ABC Medical Center, Mexico City, Mexico; Ortomove, Mexico City, Mexico.
Zitieren
APA
Domb, B. G., Quesada-Jimenez, R., Barda, S. R., Defort, T. M., Kuhns, B. D., & Kahana-Rojkind, A. H. (2026). Ten-Year Functional Outcomes Following Robotic-Assisted Total Hip Arthroplasty: A Case Series. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2026.01.052
Vancouver
Domb BG, Quesada-Jimenez R, Barda SR, Defort TM, Kuhns BD, Kahana-Rojkind AH. Ten-Year Functional Outcomes Following Robotic-Assisted Total Hip Arthroplasty: A Case Series. The Journal of Arthroplasty. 2026. doi:10.1016/j.arth.2026.01.052
BibTeX
@article{Domb2026,
author = {Domb, Benjamin G and Quesada-Jimenez, Roger and Barda, Shahar R and Defort, Tyler M and Kuhns, Benjamin D and Kahana-Rojkind, Ady H},
title = {Ten-Year Functional Outcomes Following Robotic-Assisted Total Hip Arthroplasty: A Case Series},
journal = {The Journal of Arthroplasty},
year = {2026},
doi = {10.1016/j.arth.2026.01.052}
}
EUVIMED