Experimental and numerical failure analysis of Thompson hip prosthesis

Ali Motameni, Ömer Can Farukoğlu, Rıza Gürbüz iD, İhsan Korkut

Bio-Medical Materials and Engineering · 2026

DOI: 10.1177/09592989251353462 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bio-Medical Materials and Engineering, 2026. Verfasst von Ali Motameni und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Metallurgical and Materials Engineering, Middle East Technical University, Ankara, Turkey. Hauptthemen laut MEDLINE: Hip Prosthesis, Prosthesis Failure, Arthroplasty, Replacement, Hip. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

There are different surgical procedures to fix femoral head-neck fractures, such as total hip arthroplasty and hemiarthroplasty. Under optimal conditions, the inserted prosthesis should last a long time, possibly a lifetime, with only trace amounts of wear each year due to the friction between the femur bone and the prosthesis stem. However, in some cases, failure due to excessive wear, creep, fatigue, corrosion, etc., can occur.

Objective

This study investigates the failure causes of a Thompson hip prosthesis both experimentally and numerically.

Methods

The stem of the prosthesis, which is inserted into the femur, broke inside a patient's body over time. Following the removal surgery, the severely damaged and fractured stem was examined to determine the root causes of the failure. For this purpose, fractographic examination of the fractured surfaces was conducted with scanning electron microscope (SEM). Microstructural analyses were performed using optical microscope, and the chemical composition of the prosthesis was analyzed with energy dispersive spectroscopy (EDS). Vickers hardness (HV30) test was conducted on the femoral stem. Additionally, finite element method (FEM) was applied to estimate the forces acting on the prosthesis.

Results

It was observed that fatigue cracks initiated and propagated from the outer surface of the femoral stem at locations very close to the maximum von Mises stresses observed in the FEM analysis. However, the load magnitudes in the FEM analysis were not high enough to initiate any cracks.

Conclusion

It is considered that crack initiation occurred due to material defects from the prosthesis manufacturing process, and the cyclic loading during body motion propagated these cracks. Ultimately, the fracture of the Thompson hip prosthesis occurred.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hip ProsthesisProsthesis FailureArthroplasty, Replacement, HipHumansFinite Element AnalysisProsthesis DesignStress, MechanicalMaterials TestingFrictionFemurHardnessEquipment Failure AnalysisMicroscopy, Electron, ScanningSurface Properties

Stichwörter der Autor:innen

Thompson hip prosthesisfailure analysisfemoral stemhip joint failureimplants

Autor:innen und Institutionen

  • Department of Metallurgical and Materials Engineering, Middle East Technical University, Ankara, Turkey.
  • Department of Manufacturing Engineering, Gazi University, Ankara, Turkey.

ORCID-Profile: Rıza Gürbüz

Zitieren

APA

Motameni, A., Farukoğlu, Ö. C., Gürbüz, R., & Korkut, İ. (2026). Experimental and numerical failure analysis of Thompson hip prosthesis. Bio-Medical Materials and Engineering. https://doi.org/10.1177/09592989251353462

Vancouver

Motameni A, Farukoğlu ÖC, Gürbüz R, Korkut İ. Experimental and numerical failure analysis of Thompson hip prosthesis. Bio-Medical Materials and Engineering. 2026. doi:10.1177/09592989251353462

BibTeX
@article{Motameni2026,
  author = {Motameni, Ali and Farukoğlu, Ömer Can and Gürbüz, Rıza and Korkut, İhsan},
  title = {Experimental and numerical failure analysis of Thompson hip prosthesis},
  journal = {Bio-Medical Materials and Engineering},
  year = {2026},
  doi = {10.1177/09592989251353462}
}
Kostenlos starten →