EUVIMEDEUVIMED entdecken
Crossref

Total Hip Arthroplasty: Effect of Head Size, Offset Gap, Offset Angle, Trunnion Length and Fixation on Trunnionosis of Hip Implant

Ali Murat Soydan, Dünya Sena Yıldız, Ömer Faruk Bilgen, Mehmet Sinan Uyanık

International Journal for Numerical Methods in Biomedical Engineering · 2025

DOI: 10.1002/cnm.70106 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, 2025. Verfasst von Ali Murat Soydan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Gebze Technical University, Institute of Energy Technologies, Kocaeli, Turkey. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: İnogen Energy Technologies.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Trunnionosis can be defined as the wear of the femoral head–neck contact. This phenomenon is increasingly recognized as a major factor in hip arthroplasty failure. The selection of a highly compatible head has become crucial to reduce the trunnionosis effects in orthopedic surgery. In this study, the biomechanical behavior and wear corrosion of the trunnion of hip implants with 28, 32, 36, 40, and 44 mm head sizes and ±3 mm head offset gap configurations have been investigated using finite element methods. The hip implant configurations were modeled in Autodesk Fusion 360, and the simulations of the static, modal, and dynamic finite element analyses were performed using ANSYS. The effects of different head sizes and offset gap configurations, offset angles, fixation models, and trunnion lengths on wear corrosion are analyzed based on stress, deformation, penetration, sliding distance, frequency vibrational effects, and moment reactions. The results show that the configuration with −3 mm offset, 28 mm head size, 132° offset angle, and type 3 fixation results in higher stability; the −3 mm offset, 28 mm head size, 127° offset angle, and type 2 fixation configuration leads to lower moment reaction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisHumansFinite Element AnalysisProsthesis DesignBiomechanical PhenomenaFemur HeadProsthesis FailureStress, Mechanical

Stichwörter der Autor:innen

dynamic analysisfinite element method (FEM)static analysistotal hip arthroplasty (THA)trunnionosis

Autor:innen und Institutionen

  • Gebze Technical University, Institute of Energy Technologies, Kocaeli, Turkey.
  • Engineering Faculty, Department of Mechanical Engineering, Gebze Technical University, Kocaeli, Turkey.
  • Medicabil Hospital, Bursa, Turkey.

Förderung

  • İnogen Energy Technologies

Zitieren

APA

Soydan, A. M., Yıldız, D. S., Bilgen, Ö. F., & Uyanık, M. S. (2025). Total Hip Arthroplasty: Effect of Head Size, Offset Gap, Offset Angle, Trunnion Length and Fixation on Trunnionosis of Hip Implant. International Journal for Numerical Methods in Biomedical Engineering. https://doi.org/10.1002/cnm.70106

Vancouver

Soydan AM, Yıldız DS, Bilgen ÖF, Uyanık MS. Total Hip Arthroplasty: Effect of Head Size, Offset Gap, Offset Angle, Trunnion Length and Fixation on Trunnionosis of Hip Implant. International Journal for Numerical Methods in Biomedical Engineering. 2025. doi:10.1002/cnm.70106

BibTeX
@article{Soydan2025,
  author = {Soydan, Ali Murat and Yıldız, Dünya Sena and Bilgen, Ömer Faruk and Uyanık, Mehmet Sinan},
  title = {Total Hip Arthroplasty: Effect of Head Size, Offset Gap, Offset Angle, Trunnion Length and Fixation on Trunnionosis of Hip Implant},
  journal = {International Journal for Numerical Methods in Biomedical Engineering},
  year = {2025},
  doi = {10.1002/cnm.70106}
}
Kostenlos starten →