EUVIMEDEUVIMED entdecken
Crossref

Automatic Detection of B-Lines in Lung Ultrasound Based on the Evaluation of Multiple Characteristic Parameters Using Raw RF Data

Wuyi Shen iD, Yuancheng Zhang, Haoyu Zhang, Hui Zhong, Mingxi Wan

Ultrasonic Imaging · 2025

DOI: 10.1177/01617346251330111 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ultrasonic Imaging, 2025. Verfasst von Wuyi Shen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi, China. Hauptthemen laut MEDLINE: Lung, Image Processing, Computer-Assisted. Die Arbeit nennt 42 Literaturangaben. Gefördert von: Natural Science Basic Research Program of Shaanxi Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

B-line artifacts in lung ultrasound, pivotal for diagnosing pulmonary conditions, warrant automated recognition to enhance diagnostic accuracy. In this paper, a lung ultrasound B-line vertical artifact identification method based on radio frequency (RF) signal was proposed. B-line regions were distinguished from non-B-line regions by inputting multiple characteristic parameters into nonlinear support vector machine (SVM). Six characteristic parameters were evaluated, including permutation entropy, information entropy, kurtosis, skewness, Nakagami shape factor, and approximate entropy. Following the evaluation that demonstrated the performance differences in parameter recognition, Principal Component Analysis (PCA) was utilized to reduce the dimensionality to a four-dimensional feature set for input into a nonlinear Support Vector Machine (SVM) for classification purposes. Four types of experiments were conducted: a sponge with dripping water model, gelatin phantoms containing either glass beads or gelatin droplets, and in vivo experiments. By employing precise feature selection and analyzing scan lines rather than full images, this approach significantly reduced the dependency on large image datasets without compromising discriminative accuracy. The method exhibited performance comparable to contemporary image-based deep learning approaches, which, while highly effective, typically necessitate extensive data for training and require expert annotation of large datasets to establish ground truth. Owing to the optimized architecture of our model, efficient sample recognition was achieved, with the capability to process between 27,000 and 33,000 scan lines per second (resulting in a frame rate exceeding 100 FPS, with 256 scan lines per frame), thus supporting real-time analysis. The results demonstrate that the accuracy of the method to classify a scan line as belonging to a B-line region was up to 88%, with sensitivity reaching up to 90%, specificity up to 87%, and an F1-score up to 89%. This approach effectively reflects the performance of scan line classification pertinent to B-line identification. Our approach reduces the reliance on large annotated datasets, thereby streamlining the preprocessing phase.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LungImage Processing, Computer-AssistedUltrasonographyPhantoms, ImagingHumansSupport Vector MachineArtifactsRadio Waves

Stichwörter der Autor:innen

B-line detectioncharacteristic parameter evaluationlung ultrasound artifactsnonlinear support vector machine

Autor:innen und Institutionen

  • Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi, China.
  • Key Laboratory of Biomedical Information Engineering of Ministry of Education, Xi'an, Shaanxi, China.

ORCID-Profile: Wuyi Shen

Förderung

  • Natural Science Basic Research Program of Shaanxi Province
  • National Natural Science Foundation of China

Zitieren

APA

Shen, W., Zhang, Y., Zhang, H., Zhong, H., & Wan, M. (2025). Automatic Detection of B-Lines in Lung Ultrasound Based on the Evaluation of Multiple Characteristic Parameters Using Raw RF Data. Ultrasonic Imaging. https://doi.org/10.1177/01617346251330111

Vancouver

Shen W, Zhang Y, Zhang H, Zhong H, Wan M. Automatic Detection of B-Lines in Lung Ultrasound Based on the Evaluation of Multiple Characteristic Parameters Using Raw RF Data. Ultrasonic Imaging. 2025. doi:10.1177/01617346251330111

BibTeX
@article{Shen2025,
  author = {Shen, Wuyi and Zhang, Yuancheng and Zhang, Haoyu and Zhong, Hui and Wan, Mingxi},
  title = {Automatic Detection of B-Lines in Lung Ultrasound Based on the Evaluation of Multiple Characteristic Parameters Using Raw RF Data},
  journal = {Ultrasonic Imaging},
  year = {2025},
  doi = {10.1177/01617346251330111}
}
Kostenlos starten →