Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users
Investigative Opthalmology & Visual Science · 2023
DOI: 10.1167/iovs.64.14.12 ↗Kurz gefasst
Fachartikel in der Zeitschrift Investigative Opthalmology & Visual Science, 2023. Verfasst von José Ángel Pastor-Zaplana und 2 weiteren Autor:innen. Beteiligte Einrichtung: Instituto de Neurociencias, Universidad Miguel Hernández-CSIC, Sant Joan d'Alacant, Spain. Hauptthemen laut MEDLINE: Contact Lenses, Lacrimal Apparatus Diseases, Contact Lenses, Hydrophilic, Dry Eye Syndromes. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
The purpose of this study was to analyze the differences in corneal sensory nerve functionality in young asymptomatic (CL-A) and symptomatic (CL-S) contact lens (CL) users.
Methods
CL wearers (23.8 ± 1.0 years, n = 31) were classified as CL-S with an Ocular Surface Disease Index (OSDI) ≥ 13 (n = 14) or CL-A. Users of eye glasses (EG; 24.5 ± 0.8 years, n = 29) with OSDI < 13 participated as controls. The sensations evoked by mechanical, chemical (gas esthesiometer), and cold (4°C saline drops) stimuli were measured using the Visual Analogue Scales (VASs). Moreover, tear volume, tear break up time (TBUT), blinking frequency (BF), and ocular surface temperature (OST; IR thermography) were also measured.
Results
Mechanical and chemical stimuli produced similar scores in the CL-A and EG participants, although the CL-A subjects referred to stronger irritation (p < 0.05). Likewise, the VAS intensity in response to cold stimuli did not differ between CL-A and EG subjects, while the ability to detect cold was significantly worse in CL-S users (p < 0.05). CL-A users had a similar tear volume, a higher BF (p < 0.01) and shorter TBUT (p < 0.001) to EG wearers, and blinking and TBUT were also altered significantly in CL-S users (p < 0.01). Interestingly, the OST was significantly lower in CL-A users (p < 0.05) than in EG wearers, but not in CL-S users.
Conclusions
Using CLs modifies corneal sensitivity, blinking and tearing in young volunteers. Even if they have yet to develop clinical signs of inflammation, they display changes in corneal sensitivity consistent with the sensitization of corneal nociceptors and the inhibition cold thermoreceptors, phenomena that occur under inflammatory conditions. The differences in corneal sensitivity and OST between CL-A and CL-S users could reflect the extent of nerve damage and inflammation at the ocular surface.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Instituto de Neurociencias, Universidad Miguel Hernández-CSIC, Sant Joan d'Alacant, Spain.
- Departamento de Patología y Cirugía, Universidad Miguel Hernández de Elche, Sant Joan d'Alacant, Spain.
- Instituto de Investigación Biomédica y Sanitaria de Alicante, Alicante, Spain.
Zitieren
APA
Pastor-Zaplana, J. Á., Gallar, J., & Acosta, M. C. (2023). Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.64.14.12
Vancouver
Pastor-Zaplana JÁ, Gallar J, Acosta MC. Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users. Investigative Opthalmology & Visual Science. 2023. doi:10.1167/iovs.64.14.12
BibTeX
@article{PastorZaplana2023,
author = {Pastor-Zaplana, José Ángel and Gallar, Juana and Acosta, M Carmen},
title = {Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users},
journal = {Investigative Opthalmology & Visual Science},
year = {2023},
doi = {10.1167/iovs.64.14.12}
}
EUVIMED