EUVIMEDEUVIMED entdecken
Crossref

Influence of Contact Lens Parameters on Tear Film Dynamics

Darshan Ramasubramanian, José Luis Hernández-Verdejo, José Manuel López-Alonso

Bulletin of Mathematical Biology · 2025

DOI: 10.1007/s11538-025-01425-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bulletin of Mathematical Biology, 2025. Verfasst von Darshan Ramasubramanian und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain. Hauptthemen laut MEDLINE: Tears, Models, Biological, Contact Lenses. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 63 Literaturangaben. Gefördert von: HORIZON EUROPE Framework Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study employs a computational model to simulate the dynamics of tear fluid and tear film in conjunction with contact lens motion, examining the interplay between diverse contact lens characteristics-such as material, design, and dimensions-and key ocular factors like dry eye conditions, corneal size, and blink rate. These interactions are critical for customising lens fit to maximise wearer comfort. Utilising optical measurements from a single participant, the study integrates data on tear meniscus size, blink velocity, and palpebral fissure height with sixteen different contact lens parameters, including Young's modulus, thickness, diameter, and curvature. Correlation analyses were conducted to determine the impact of these parameters on the dynamics of the tear fluid and overall tear film. Results show that the diameter and Young's modulus of the contact lens significantly influence pre-lens tear film thickness, with robust, statistically significant correlations. In contrast, lens thickness and base curve showed minimal impact, as evidenced by weak and non-significant correlations. These findings underscore the critical roles of lens diameter and Young's modulus in enhancing the stability and distribution of tear fluid, thereby improving wearer comfort and advancing contact lens design.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TearsModels, BiologicalContact LensesHumansComputer SimulationMathematical ConceptsDry Eye SyndromesBlinkingElastic ModulusCorneaComputational BiologyEquipment Design

Stichwörter der Autor:innen

Contact lens designCorrelation analysisTear film dynamicsTear fluidWearer comfort

Autor:innen und Institutionen

  • Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain.
  • Alain Afflelou Óptico, Portugal, Av. António Augusto de Aguiar, 11, 1050-016, Lisbon, Portugal.
  • Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain. jmlopez@ucm.es.

Förderung

  • HORIZON EUROPE Framework Programme

Zitieren

APA

Ramasubramanian, D., Hernández-Verdejo, J. L., & López-Alonso, J. M. (2025). Influence of Contact Lens Parameters on Tear Film Dynamics. Bulletin of Mathematical Biology. https://doi.org/10.1007/s11538-025-01425-1

Vancouver

Ramasubramanian D, Hernández-Verdejo JL, López-Alonso JM. Influence of Contact Lens Parameters on Tear Film Dynamics. Bulletin of Mathematical Biology. 2025. doi:10.1007/s11538-025-01425-1

BibTeX
@article{Ramasubramanian2025,
  author = {Ramasubramanian, Darshan and Hernández-Verdejo, José Luis and López-Alonso, José Manuel},
  title = {Influence of Contact Lens Parameters on Tear Film Dynamics},
  journal = {Bulletin of Mathematical Biology},
  year = {2025},
  doi = {10.1007/s11538-025-01425-1}
}
Kostenlos starten →