EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ocular effects of exposure to low‐humidity environment with contact lens wear: A pilot study

Megan Vaughan iD, Nery García-Porta iD, Juan Tabernero, Javier Gantes-Nuñez, Pablo Artal, Shahina Pardhan

Ophthalmic and Physiological Optics · 2024

DOI: 10.1111/opo.13308 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2024. Verfasst von Megan Vaughan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK. Hauptthemen laut MEDLINE: Humidity, Blinking. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union-NextGenerationEU, Anglia Ruskin University, H2020 Marie Skłodowska-Curie Actions.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the ocular effects of exposure to a low‐humidity environment with and without contact lens (CL) wear using various non‐invasive tests.

Methods

Fourteen habitual soft CL wearers were exposed to controlled low humidity (5% relative humidity [RH]) in an environmental chamber for 90 min on two separate occasions. First, when wearing their habitual spectacles and then, on a separate visit, when wearing silicone hydrogel CLs that were fitted specifically for this purpose. All participants had adapted to the new CL prior to data collection. Three non‐invasive objective measurements were taken at each visit: blinking rate, objective ocular scatter (measured using the objective scatter index) and ocular surface cooling rate (measured using a long‐wave infrared thermal camera). At each visit, measurements were taken before the exposure in comfortable environmental conditions (RH: 45%), and after exposure to environmental stress (low humidity, RH: 5%).

Results

CL wearers showed increased blinking rate ( p < 0.005) and ocular scatter ( p = 0.03) but similar cooling rate of the ocular surface ( p = 0.08) when compared with spectacle wear in comfortable environmental conditions. The exposure to low humidity increased the blinking rate significantly with both types of corrections ( p = 0.01). Interestingly, ocular scatter ( p = 0.96) and cooling rate ( p = 0.73) were not significantly different before and after exposure to low humidity. There were no significant two‐way interactions between correction and exposure in any of the measurements.

Conclusions

CLs significantly increased the blinking rate, which prevented a quick degradation of the tear film integrity as it was refreshed more regularly. It is hypothesised that the increased blinking rate in CL wearers aids in maintaining ocular scatter quality and cooling rate when exposed to a low‐humidity environment. These results highlight the importance of blinking in maintaining tear film stability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HumidityBlinkingHumansPilot ProjectsAdultMaleFemaleYoung AdultContact Lenses, HydrophilicTearsContact Lenses

Stichwörter der Autor:innen

adverse environmentblinkingcontact lensenvironmental chamber

Autor:innen und Institutionen

  • Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK.
  • Applied Physics Department, Optics and Optometry Faculty, University of Santiago de Compostela, Santiago, Spain.
  • Institute of Materials (iMATUS), University of Santiago de Compostela, Santiago, Spain.
  • Department of Electromagnetism and Electronics, University of Murcia, Murcia, Spain.
  • Arizona College of Optometry, Midwestern University, Glendale, Arizona, USA.
  • Laboratorio de Óptica, Centro de Investigación en Óptica y Nanofísica, Campus Espinardo, University of Murcia, Murcia, Spain.

ORCID-Profile: Megan Vaughan, Nery García-Porta

Förderung

  • European Union-NextGenerationEU
  • Anglia Ruskin University
  • H2020 Marie Skłodowska-Curie Actions

Zitieren

APA

Vaughan, M., García-Porta, N., Tabernero, J., Gantes-Nuñez, J., Artal, P., & Pardhan, S. (2024). Ocular effects of exposure to low‐humidity environment with contact lens wear: A pilot study. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13308

Vancouver

Vaughan M, García-Porta N, Tabernero J, Gantes-Nuñez J, Artal P, Pardhan S. Ocular effects of exposure to low‐humidity environment with contact lens wear: A pilot study. Ophthalmic and Physiological Optics. 2024. doi:10.1111/opo.13308

BibTeX
@article{Vaughan2024,
  author = {Vaughan, Megan and García-Porta, Nery and Tabernero, Juan and Gantes-Nuñez, Javier and Artal, Pablo and Pardhan, Shahina},
  title = {Ocular effects of exposure to low‐humidity environment with contact lens wear: A pilot study},
  journal = {Ophthalmic and Physiological Optics},
  year = {2024},
  doi = {10.1111/opo.13308}
}
Kostenlos starten →