EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

The Changes in Ocular Biomechanical Response Parameters and Intraocular Pressure After Surgical Treatment for Thyroid Eye Disease

Yun Hsia, Yi-Hsuan Wei, Shu-Lang Liao

Investigative Opthalmology & Visual Science · 2023

DOI: 10.1167/iovs.64.10.31 ↗

At a glance

Journal article in Investigative Opthalmology & Visual Science, 2023. Written by Yun Hsia and 2 co-authors. Institution: Department of Ophthalmology, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu, Taiwan. Major MEDLINE topics: Graves Ophthalmopathy, Glaucoma. Cited 6 times so far (Crossref); 49 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To investigate changes in ocular biomechanical response parameters and intraocular pressure (IOP) in patients with thyroid eye disease (TED) undergoing orbital decompression or anterior blepharotomy.

Methods

Eighty-three eyes from 46 patients receiving orbital decompression (the orbital decompression group) and 45 eyes from 28 patients receiving anterior blepharotomy (the anterior blepharotomy group) were retrospectively enrolled from a tertiary center. Corvis ST tonometry was used to assess ocular biomechanical response and biomechanically corrected IOP (bIOP) pre- and postoperatively. Non-contact tonometry (IOP-NCT) was also performed.

Results

In the anterior blepharotomy group, the margin reflex distance decreased (P < 0001). The highest concavity radius (P = 0.026) and whole eye movement (P = 0.003) increased. Neither IOP-NCT nor bIOP had a significant change. In the orbital decompression group, the extent of exophthalmos decreased (P < 0.001). The A2 length (P = 0.009) decreased. The bIOP did not show a significant change (16.4 ± 2.7 vs. 16.7 ± 4.5; P = 0.415), but the IOP-NCT decreased significantly (17.5 ± 3.3 vs. 16.0 ± 3.3; P < 0.001). Higher baseline IOP-NCT (β = -0.40, P < 0.001) and greater reduction in stiffness parameter A1 (SP-A1; β = 0.05, P = 0.002) were associated with more significant IOP-NCT reduction after the orbital decompression.

Conclusions

Ocular biomechanical response parameters may change after TED surgery, potentially affecting IOP measurements, particularly in patients receiving orbital decompression.

Subjects

MeSH terms (MEDLINE)

Graves OphthalmopathyGlaucomaHumansIntraocular PressureRetrospective StudiesCorneaTonometry, OcularEyelidsBiomechanical Phenomena

Authors and institutions

  • Department of Ophthalmology, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu, Taiwan.
  • Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan.
  • College of Medicine, National Taiwan University, Taipei, Taiwan.

Cite

APA

Hsia, Y., Wei, Y. H., & Liao, S. L. (2023). The Changes in Ocular Biomechanical Response Parameters and Intraocular Pressure After Surgical Treatment for Thyroid Eye Disease. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.64.10.31

Vancouver

Hsia Y, Wei YH, Liao SL. The Changes in Ocular Biomechanical Response Parameters and Intraocular Pressure After Surgical Treatment for Thyroid Eye Disease. Investigative Opthalmology & Visual Science. 2023. doi:10.1167/iovs.64.10.31

BibTeX
@article{Hsia2023,
  author = {Hsia, Yun and Wei, Yi-Hsuan and Liao, Shu-Lang},
  title = {The Changes in Ocular Biomechanical Response Parameters and Intraocular Pressure After Surgical Treatment for Thyroid Eye Disease},
  journal = {Investigative Opthalmology & Visual Science},
  year = {2023},
  doi = {10.1167/iovs.64.10.31}
}
Start for free →