The Changes in Ocular Biomechanical Response Parameters and Intraocular Pressure After Surgical Treatment for Thyroid Eye Disease
Investigative Opthalmology & Visual Science · 2023
DOI: 10.1167/iovs.64.10.31 ↗Kurz gefasst
Fachartikel in der Zeitschrift Investigative Opthalmology & Visual Science, 2023. Verfasst von Yun Hsia und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu, Taiwan. Hauptthemen laut MEDLINE: Graves Ophthalmopathy, Glaucoma. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
To investigate changes in ocular biomechanical response parameters and intraocular pressure (IOP) in patients with thyroid eye disease (TED) undergoing orbital decompression or anterior blepharotomy.
Methods
Eighty-three eyes from 46 patients receiving orbital decompression (the orbital decompression group) and 45 eyes from 28 patients receiving anterior blepharotomy (the anterior blepharotomy group) were retrospectively enrolled from a tertiary center. Corvis ST tonometry was used to assess ocular biomechanical response and biomechanically corrected IOP (bIOP) pre- and postoperatively. Non-contact tonometry (IOP-NCT) was also performed.
Results
In the anterior blepharotomy group, the margin reflex distance decreased (P < 0001). The highest concavity radius (P = 0.026) and whole eye movement (P = 0.003) increased. Neither IOP-NCT nor bIOP had a significant change. In the orbital decompression group, the extent of exophthalmos decreased (P < 0.001). The A2 length (P = 0.009) decreased. The bIOP did not show a significant change (16.4 ± 2.7 vs. 16.7 ± 4.5; P = 0.415), but the IOP-NCT decreased significantly (17.5 ± 3.3 vs. 16.0 ± 3.3; P < 0.001). Higher baseline IOP-NCT (β = -0.40, P < 0.001) and greater reduction in stiffness parameter A1 (SP-A1; β = 0.05, P = 0.002) were associated with more significant IOP-NCT reduction after the orbital decompression.
Conclusions
Ocular biomechanical response parameters may change after TED surgery, potentially affecting IOP measurements, particularly in patients receiving orbital decompression.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Ophthalmology, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu, Taiwan.
- Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan.
- College of Medicine, National Taiwan University, Taipei, Taiwan.
Zitieren
APA
Hsia, Y., Wei, Y. H., & Liao, S. L. (2023). The Changes in Ocular Biomechanical Response Parameters and Intraocular Pressure After Surgical Treatment for Thyroid Eye Disease. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.64.10.31
Vancouver
Hsia Y, Wei YH, Liao SL. The Changes in Ocular Biomechanical Response Parameters and Intraocular Pressure After Surgical Treatment for Thyroid Eye Disease. Investigative Opthalmology & Visual Science. 2023. doi:10.1167/iovs.64.10.31
BibTeX
@article{Hsia2023,
author = {Hsia, Yun and Wei, Yi-Hsuan and Liao, Shu-Lang},
title = {The Changes in Ocular Biomechanical Response Parameters and Intraocular Pressure After Surgical Treatment for Thyroid Eye Disease},
journal = {Investigative Opthalmology & Visual Science},
year = {2023},
doi = {10.1167/iovs.64.10.31}
}
EUVIMED