Comparisonison of Geometric Accuracy of Low-Dose and Standard-Dose Dental CBCT Imaging Protocols in CAD/CAM-Guided Dental Implant Surgery

Silvan Unger, Marion Penzenstadler, Adib Al-Haj Husain, Daniel Wiedemeier, Bernd Stadlinger, Silvio Valdec

International Journal of Oral and Maxillofacial Implants · 2023

DOI: 10.11607/jomi.9851 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Oral and Maxillofacial Implants, 2023. Verfasst von Silvan Unger und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Dental Implantation, Endosseous, Dental Implants, Imaging, Three-Dimensional, Spiral Cone-Beam Computed Tomography. Die Arbeit wurde bisher 5-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This preclinical comparison study assessed the diagnostic accuracy of low-dose CBCT protocols compared with standard-dose protocols in digital implant treatment planning and template-guided implant surgery. MATERIALS AND METHODS: Thirty mandibles of pig cadavers underwent both CBCT protocols on an Orthophos SL Unit (Dentsply-Sirona). Surface scans of the regions of interest were performed to create a digital diagnostic wax-up followed by 120 subsequent implant plannings (one implant per quadrant). Simple randomization (1:1) was assessed to assign each quadrant into one of the imaging protocols. Sixty implant surgical guides were manufactured using CAD/CAM technology, followed by the fully guided placement of 60 implants following the surgical protocol in randomized order. Geometric accuracy between the planned and definitive implant position was determined regarding apical distances between the central axes and angle deviation. Descriptive statistics and linear regressions were used for the statistical analysis of the data. RESULTS: Regarding implant apex deviation using low-dose CBCT, the following differences were observed: apical deviation of 0.75 ± 0.63 mm and angular deviation of 2.5 ± 2.12 degrees, while the standard-dose CBCT showed the following results: apical deviation of 0.92 ± 0.55 mm and angular deviation of 3.06 ± 2.12 degrees. The regression analyses could not show evidence for a significant difference between the two CBCT protocols, neither with regard to the apical distance nor in view of the angular deviation. CONCLUSION: Low-dose CBCT imaging protocols providing accurate 3D anatomical information with an improved benefit-risk ratio according to the as low as diagnostically acceptable (ALADA) principle could become a promising option as a primary diagnostic modality as well as for radiologic follow-up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Implantation, EndosseousDental ImplantsImaging, Three-DimensionalSpiral Cone-Beam Computed TomographySurgery, Computer-AssistedAnimalsCone-Beam Computed TomographyRadiation DosageSwine

Substanzen

Dental Implants

Zitieren

APA

Unger, S., Penzenstadler, M., Husain, A. A., Wiedemeier, D., Stadlinger, B., & Valdec, S. (2023). Comparisonison of Geometric Accuracy of Low-Dose and Standard-Dose Dental CBCT Imaging Protocols in CAD/CAM-Guided Dental Implant Surgery. International Journal of Oral and Maxillofacial Implants. https://doi.org/10.11607/jomi.9851

Vancouver

Unger S, Penzenstadler M, Husain AA, Wiedemeier D, Stadlinger B, Valdec S. Comparisonison of Geometric Accuracy of Low-Dose and Standard-Dose Dental CBCT Imaging Protocols in CAD/CAM-Guided Dental Implant Surgery. International Journal of Oral and Maxillofacial Implants. 2023. doi:10.11607/jomi.9851

BibTeX
@article{Unger2023,
  author = {Unger, Silvan and Penzenstadler, Marion and Husain, Adib Al-Haj and Wiedemeier, Daniel and Stadlinger, Bernd and Valdec, Silvio},
  title = {Comparisonison of Geometric Accuracy of Low-Dose and Standard-Dose Dental CBCT Imaging Protocols in CAD/CAM-Guided Dental Implant Surgery},
  journal = {International Journal of Oral and Maxillofacial Implants},
  year = {2023},
  doi = {10.11607/jomi.9851}
}
Kostenlos starten →