Comparisonison of Geometric Accuracy of Low-Dose and Standard-Dose Dental CBCT Imaging Protocols in CAD/CAM-Guided Dental Implant Surgery
International Journal of Oral and Maxillofacial Implants · 2023
DOI: 10.11607/jomi.9851 ↗At a glance
Journal article in International Journal of Oral and Maxillofacial Implants, 2023. Written by Silvan Unger and 5 co-authors. Major MEDLINE topics: Dental Implantation, Endosseous, Dental Implants, Imaging, Three-Dimensional, Spiral Cone-Beam Computed Tomography. Cited 5 times so far (Crossref).
Abstract (original language)
PURPOSE: This preclinical comparison study assessed the diagnostic accuracy of low-dose CBCT protocols compared with standard-dose protocols in digital implant treatment planning and template-guided implant surgery. MATERIALS AND METHODS: Thirty mandibles of pig cadavers underwent both CBCT protocols on an Orthophos SL Unit (Dentsply-Sirona). Surface scans of the regions of interest were performed to create a digital diagnostic wax-up followed by 120 subsequent implant plannings (one implant per quadrant). Simple randomization (1:1) was assessed to assign each quadrant into one of the imaging protocols. Sixty implant surgical guides were manufactured using CAD/CAM technology, followed by the fully guided placement of 60 implants following the surgical protocol in randomized order. Geometric accuracy between the planned and definitive implant position was determined regarding apical distances between the central axes and angle deviation. Descriptive statistics and linear regressions were used for the statistical analysis of the data. RESULTS: Regarding implant apex deviation using low-dose CBCT, the following differences were observed: apical deviation of 0.75 ± 0.63 mm and angular deviation of 2.5 ± 2.12 degrees, while the standard-dose CBCT showed the following results: apical deviation of 0.92 ± 0.55 mm and angular deviation of 3.06 ± 2.12 degrees. The regression analyses could not show evidence for a significant difference between the two CBCT protocols, neither with regard to the apical distance nor in view of the angular deviation. CONCLUSION: Low-dose CBCT imaging protocols providing accurate 3D anatomical information with an improved benefit-risk ratio according to the as low as diagnostically acceptable (ALADA) principle could become a promising option as a primary diagnostic modality as well as for radiologic follow-up.
Subjects
MeSH terms (MEDLINE)
Substances
Cite
APA
Unger, S., Penzenstadler, M., Husain, A. A., Wiedemeier, D., Stadlinger, B., & Valdec, S. (2023). Comparisonison of Geometric Accuracy of Low-Dose and Standard-Dose Dental CBCT Imaging Protocols in CAD/CAM-Guided Dental Implant Surgery. International Journal of Oral and Maxillofacial Implants. https://doi.org/10.11607/jomi.9851
Vancouver
Unger S, Penzenstadler M, Husain AA, Wiedemeier D, Stadlinger B, Valdec S. Comparisonison of Geometric Accuracy of Low-Dose and Standard-Dose Dental CBCT Imaging Protocols in CAD/CAM-Guided Dental Implant Surgery. International Journal of Oral and Maxillofacial Implants. 2023. doi:10.11607/jomi.9851
BibTeX
@article{Unger2023,
author = {Unger, Silvan and Penzenstadler, Marion and Husain, Adib Al-Haj and Wiedemeier, Daniel and Stadlinger, Bernd and Valdec, Silvio},
title = {Comparisonison of Geometric Accuracy of Low-Dose and Standard-Dose Dental CBCT Imaging Protocols in CAD/CAM-Guided Dental Implant Surgery},
journal = {International Journal of Oral and Maxillofacial Implants},
year = {2023},
doi = {10.11607/jomi.9851}
}
EUVIMED