EUVIMEDEUVIMED entdecken
Crossref

Effect of pilot-guided implant placement concept on the accuracy of osteotomy preparation and implant placement

Shruti Sharma, Emilie Tan, Britney Tran, Hui Y Siow, Elshadaie Tafesse, Yoong H J Thong, Row J M Tan, Jungwoo Son, Lisa Todaro, Josephine Teo, Jaafar Abduo

Journal of Oral Science · 2024 · 66 (1) · 20-25

DOI: 10.2334/josnusd.23-0157 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Oral Science, 2024. Verfasst von Shruti Sharma und 10 weiteren Autor:innen. Beteiligte Einrichtung: Restorative Section, Melbourne Dental School, Melbourne University. Hauptthemen laut MEDLINE: Surgery, Computer-Assisted, Dental Implants. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the accuracy of osteotomy preparation and implant placement for 3 pilot-guided (PG) concepts, namely, a surgical template with a metal sleeve (MS), a surgical template with an in-built nonmetal sleeve (NMS), and a surgical template with an in-built nonmetal sleeve for round bur indentation (RB). METHODS: Surgical models with missing maxillary molars were studied. The MS templates were designed to accept metal sleeves, while the NMS and RB templates were designed with in-built nonmetal sleeves. Ten templates were tested per group (n = 10). After each step (pilot drilling, 2nd drilling, 3rd drilling, profiling, and implant placement), the surgical model was scanned and compared against the planning model to determine maximum horizontal deviation (MHD) and maximum angle deviation (MAD). RESULTS: The MS and NMS templates exhibited a similar increase in MHD with successive drilling steps. The MAD for the pilot drilling step was significantly lower for MS than for the other groups. However, the differences among groups for MHD and MAD diminished in later steps. All templates had an MHD of 1.0 mm or less and an MAD less than 8°. CONCLUSION: The investigated PG implant placement concepts resulted in similar deviations in the placed implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgery, Computer-AssistedDental ImplantsDental Implantation, EndosseousImaging, Three-DimensionalOsteotomyCone-Beam Computed Tomography

Stichwörter der Autor:innen

computer-assisteddeviationsurgical guidetemplatethree-dimensional printing

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Restorative Section, Melbourne Dental School, Melbourne University.

Zitieren

APA

Sharma, S., Tan, E., Tran, B., Siow, H. Y., Tafesse, E., Thong, Y. H. J., Tan, R. J. M., Son, J., Todaro, L., Teo, J., & Abduo, J. (2024). Effect of pilot-guided implant placement concept on the accuracy of osteotomy preparation and implant placement. Journal of Oral Science, 66(1), 20-25. https://doi.org/10.2334/josnusd.23-0157

Vancouver

Sharma S, Tan E, Tran B, Siow HY, Tafesse E, Thong YHJ, et al. Effect of pilot-guided implant placement concept on the accuracy of osteotomy preparation and implant placement. Journal of Oral Science. 2024;66(1):20-25. doi:10.2334/josnusd.23-0157

BibTeX
@article{Sharma2024,
  author = {Sharma, Shruti and Tan, Emilie and Tran, Britney and Siow, Hui Y and Tafesse, Elshadaie and Thong, Yoong H J and Tan, Row J M and Son, Jungwoo and Todaro, Lisa and Teo, Josephine and Abduo, Jaafar},
  title = {Effect of pilot-guided implant placement concept on the accuracy of osteotomy preparation and implant placement},
  journal = {Journal of Oral Science},
  year = {2024},
  volume = {66},
  number = {1},
  pages = {20--25},
  doi = {10.2334/josnusd.23-0157}
}
Kostenlos starten →