EUVIMEDOpdag EUVIMED
Crossref

An In Vitro Study of Torque Application in Abutment Screw Tightening at the Implant-Abutment Junction in Simulated Osseointegrated Implants

Jan C Kwan

The International Journal of Oral & Maxillofacial Implants · 2025

DOI: 10.11607/jomi.11322 ↗

At a glance

Journal article in The International Journal of Oral & Maxillofacial Implants, 2025. Written by Jan C Kwan. Major MEDLINE topics: Dental Abutments, Dental Implant-Abutment Design, Osseointegration, Dental Implants. Cited 1 times so far (Crossref).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

PURPOSE: To evaluate initial torque values (ITVs) and removal torque values (RTVs) in abutment screw tightening and their impact on torque application at the implant-abutment junction (IAJ) using a biomechanical friction resistance model simulating various bone densities, with and without counter-torquing measures. MATERIALS AND METHODS: A total of 60 implant-abutment assemblies were divided into three groups that each simulated different levels of frictional resistance as follows: (1) low: 40 Ncm. The endpoint for abutment screw tightening was either reaching a preset torque value of 35 Ncm or detecting a change in the implant's angular position. ITV, RTV, and changes in angular position were recorded. One-way analysis of variance (ANOVA) and post-hoc Tukey tests were used. RESULTS: For all frictional resistance groups, abutment screws tightened with a counter-torquing device attained 35 Ncm (P > .05). Abutment screws tightened without a counter-torquing device in low and medium frictional resistance groups were unable to attain 35 Ncm prior to implant rotation. ITVs of abutment screws without counter-torque were not significantly different in the medium and high frictional resistance groups (P > .05) but were significantly different in the low frictional resistance group (P .05), regardless of counter-torquing measures; however, a high variance was observed in the low and medium frictional resistance groups. CONCLUSIONS: Under the experimental conditions, counter-torque is important to ensure that the desired torque value is applied to the implant-abutment connection in low frictional resistance. RTV is proportionally related to ITV and can be used to estimate the ITV at the IAJ.

Subjects

MeSH terms (MEDLINE)

Dental AbutmentsDental Implant-Abutment DesignOsseointegrationDental ImplantsTorqueIn Vitro TechniquesFrictionHumansDental Stress AnalysisBiomechanical PhenomenaMaterials Testing

Author keywords

bone-implant interfacecounter-torqueimplant-abutment junctionpreloadtorque

Substances

Dental Implants

Cite

APA

Kwan, J. C. (2025). An In Vitro Study of Torque Application in Abutment Screw Tightening at the Implant-Abutment Junction in Simulated Osseointegrated Implants. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.11322

Vancouver

Kwan JC. An In Vitro Study of Torque Application in Abutment Screw Tightening at the Implant-Abutment Junction in Simulated Osseointegrated Implants. The International Journal of Oral & Maxillofacial Implants. 2025. doi:10.11607/jomi.11322

BibTeX
@article{Kwan2025,
  author = {Kwan, Jan C},
  title = {An In Vitro Study of Torque Application in Abutment Screw Tightening at the Implant-Abutment Junction in Simulated Osseointegrated Implants},
  journal = {The International Journal of Oral & Maxillofacial Implants},
  year = {2025},
  doi = {10.11607/jomi.11322}
}
Start for free →