Assessment of the internal connection of an angled screw channel system
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2024.12.019 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Seoyoun Hahn und 6 weiteren Autor:innen. Beteiligte Einrichtung: Former Graduate student, Graduate Prosthodontics, Department of Restorative Dentistry, University of Washington School of Dentistry, Seattle, Wash.; …. Hauptthemen laut MEDLINE: Dental Implant-Abutment Design, Dental Implants, Bone Screws. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: The angled screw channel (ASC) design has been well accepted for implant prostheses. However, investigation into the behavior of the ASC connection is sparse. PURPOSE: The purpose of this in vitro study was to assess the effect of cyclic loading on the internal connection of an ASC system compared with straight access systems by measuring reverse torque values (RTVs) and using microcomputed tomography (µCT) imaging. MATERIAL AND METHODS: Thirty dental implants (SLActive; Institut Straumann AG) were embedded in autopolymerizing acrylic resin and divided into 3 groups: Group V0, prefabricated abutment with a straight access channel; Group V25, prefabricated abutment with a 25-degree access channel; and Group C, cemented custom abutment with straight access. All specimens were initially secured with 10 Ncm using a digital torque gauge. A subset of specimens from each group (n=4) were randomly selected and assigned for µCT imaging examination and then reimaged after tightening to 35 Ncm. All specimens were subjected to cyclic loading for 5000 cycles with a loading force of 155 ±5 N at 1.2 Hz frequency in a 37 °C water bath using a fatigue machine. Repeat µCT imaging was done after cyclic loading for the representative specimens. The changes to the internal connection were measured on µCT images using a software program, and the RTV measurement of each specimen after cyclic loading treatment was recorded. The ANOVA test was used to analyze the statistical significance of the RTVs among groups (α=.05). The paired t test was used to conduct within-group comparisons of the measurement data. RESULTS: Mean ±standard deviation of RTVs varied from 29.05 ±2.99 Ncm to 29.75 ±2.61 Ncm, with no statistically significant differences among the 3 groups (P=.820). The distances from the base of the screw head to the apex of the screw-abutment-implant (SAI) system and internal air space volume within the groups V0 and V25 decreased significantly (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Former Graduate student, Graduate Prosthodontics, Department of Restorative Dentistry, University of Washington School of Dentistry, Seattle, Wash.; and Assistant Professor, Department of Restorative Dentistry, Colorado…
- Professor and Director, Department of Restorative Dentistry, Graduate Prosthodontics, University of Washington School of Dentistry, Seattle, Wash.
- Assistant Professor, Oral Health Sciences, University of Washington School of Dentistry, Seattle, Wash.
- Private practice, Bellevue, Wash.; and Affiliate Assistant Professor, Department of Restorative Dentistry, University of Washington School of Dentistry, Seattle, Wash.
- Professor Emeritus, Department of Restorative Dentistry, Graduate Prosthodontics, University of Washington School of Dentistry, Seattle, Wash.
- Associate Professor, Department of Restorative Dentistry, Graduate Prosthodontics, University of Washington School of Dentistry, Seattle, Wash.
Zitieren
APA
Hahn, S., Ramos, V., An, J., Wadhwani, C. P. K., Rubenstein, J. E., Sutton, A., & Chung, K. H. (2025). Assessment of the internal connection of an angled screw channel system. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.12.019
Vancouver
Hahn S, Ramos V, An J, Wadhwani CPK, Rubenstein JE, Sutton A, et al. Assessment of the internal connection of an angled screw channel system. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2024.12.019
BibTeX
@article{Hahn2025,
author = {Hahn, Seoyoun and Ramos, Van and An, Jonathan and Wadhwani, Chandur P K and Rubenstein, Jeffrey E and Sutton, Alan and Chung, Kwok-Hung},
title = {Assessment of the internal connection of an angled screw channel system},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2024.12.019}
}
EUVIMED