EUVIMEDSkopri EUVIMED
Crossref

The Effect of Osteotomy Preparation Technique and Implant Diameter on Primary Stability and Bone-implant Interface of Short Implants (6 mm)

Theofilos Koutouzis, Kanika Bembey, Stavros Sofos

The International Journal of Oral & Maxillofacial Implants · 2024

DOI: 10.11607/jomi.10909 ↗

At a glance

Journal article in The International Journal of Oral & Maxillofacial Implants, 2024. Written by Theofilos Koutouzis and 2 co-authors. Major MEDLINE topics: Osteotomy, Dental Implants, Dental Implantation, Endosseous, Bone-Implant Interface.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

PURPOSE: To evaluate the effect of osteotomy preparation techniques and implant diameter on primary stability and the bone-implant interface of short implants (6 mm) when placed in bone with a high degree of cancellous content. MATERIALS AND METHODS: Overall, 90 short dental implants (6 mm; Astra Tech Implant System EV, Dentsply Sirona) were divided into nine groups based on width (narrow implants [N]: 4.2 mm; regular implants [R]: 4.8 mm; or wide implants [W]: 5.4 mm), and the type of osteotomy preparation used (standard [ST], osteotome [OT], or osseodensification [OD]) to be placed in porcine tibia plateau bone samples. The following groups were created: group N-ST, group N-OT, group N-OD, group R-ST, group R-OT, group R-OD, group W-ST, group W-OT, and group W-OD. The insertion torque and implant stability quotient (ISQ) were measured. Additionally, four implants from groups N-ST, N-OT, and N-OD were evaluated histomorphometrically. RESULTS: The insertion torque was significantly higher for implants in group W-OD compared to group W-ST (50.00 ± 14.14 Ncm vs 28.00 ± 10.85 Ncm; P = .005). Similarly, the insertion torque was significantly higher for implants in group W-OT compared to group W-ST (46.87 ± 17.10 Ncm and 28.00 ± 10.85 Ncm, respectively; P = .026). The insertion torque was also significantly higher for implants in group W-OD compared to group N-OD (50.00 ± 14.14 Ncm and 31.5 ± 15.82 Ncm, respectively; P = .04). No significant differences were observed for the percentage of bone marrow space and connective tissue in contact with the implant surface between studied groups. CONCLUSIONS: Osteotomy preparation technique in sites with a high degree of cancellous content was found to influence the implant insertion torque for short and wide implants (5.4 × 6 mm). Implant width was found to influence the insertion torque of short implants placed with the OD technique.

Subjects

MeSH terms (MEDLINE)

OsteotomyDental ImplantsDental Implantation, EndosseousBone-Implant InterfaceDental Prosthesis DesignAnimalsSwineTibiaTorqueDental Prosthesis Retention

Author keywords

bonehistologyimplantsosseodensificationosteotomestability

Substances

Dental Implants

Cite

APA

Koutouzis, T., Bembey, K., & Sofos, S. (2024). The Effect of Osteotomy Preparation Technique and Implant Diameter on Primary Stability and Bone-implant Interface of Short Implants (6 mm). The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.10909

Vancouver

Koutouzis T, Bembey K, Sofos S. The Effect of Osteotomy Preparation Technique and Implant Diameter on Primary Stability and Bone-implant Interface of Short Implants (6 mm). The International Journal of Oral & Maxillofacial Implants. 2024. doi:10.11607/jomi.10909

BibTeX
@article{Koutouzis2024,
  author = {Koutouzis, Theofilos and Bembey, Kanika and Sofos, Stavros},
  title = {The Effect of Osteotomy Preparation Technique and Implant Diameter on Primary Stability and Bone-implant Interface of Short Implants (6 mm)},
  journal = {The International Journal of Oral & Maxillofacial Implants},
  year = {2024},
  doi = {10.11607/jomi.10909}
}
Start for free →