The influence of implant channel preparation technique on the mechanical and radiological properties of bone during the dental mini-implants placement (ex-vivo experimental study)
Wiadomości Lekarskie · 2025
DOI: 10.36740/wlek/212511 ↗Kurz gefasst
Fachartikel in der Zeitschrift Wiadomości Lekarskie, 2025. Verfasst von Bohdan G Mykhajlychenko und 6 weiteren Autor:innen. Beteiligte Einrichtung: NATIONAL UNIVERSITY OF HEALTH CARE OF UKRAINE NAMED BY P. L. SHUPIK, KYIV, UKRAINE. Hauptthemen laut MEDLINE: Dental Implants, Dental Implantation, Endosseous, Osteotomy, Ribs.
Abstract (Originalsprache)
Aim
To compare the mechanical and radiological properties of animal bone after preparation with different surgical protocols (including tissue compaction/ densification) Materials and Methods: Samples of animal bone tissue (porcine ribs) were prepared according to 4 protocols: osteotomic, compaction with a bone condenser, slow (50 rpm) and osteocondensation without special burrs. After preparation, the torque was measured and relative radiological density of the bone was examined using CBCT.
Results
The torque when using the slow protocol (50 rpm) was 35.82 ± 5.10 N×cm (M = 36.48), with the standard osteotomic technique – 37.27 ± 2.14 N×cm (M = 37.40), with the bone condensors – 46.57 ± 2.72 N×cm (M = 46.75) and with osteodensification – 50.61 ± 6.77 N×cm (M = 50.16). The lowest relative x-ray density of the walls of the implantation channel was when using the osteotomy protocol (1000 rpm) – 372.85 ± 181.01 dHU (M = 374.00), with the slow protocol – 538.75 ± 167.82 dHU (M = 522.50). Slightly higher values were obtained with the use of bone condensors – 602.18±263.42 dHU (M = 549.00), and the highest was with osteodensification technique – 877.75±226.25 dHU (M = 862.50).
Conclusions
The use of bone condensors and osteodensification techniques (even without special burs) durin: the preparation of the implantation channel for mini-implants leads to progressive improvement of bone tissue.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- NATIONAL UNIVERSITY OF HEALTH CARE OF UKRAINE NAMED BY P. L. SHUPIK, KYIV, UKRAINE.
- UZHHOROD NATIONAL UNIVERSITY, UZHHOROD, UKRAINE.
- OBUKHIV CITY DENTAL POLYCLINIC, OBUKHIV, UKRAINE.
Zitieren
APA
Mykhajlychenko, B. G., Humeniuk, V. O., Mochalov, I. O., Tukalo, I. V., Vakhrusheva, T. M., Bilichenko, I. O., & Mochalov, O. O. (2025). The influence of implant channel preparation technique on the mechanical and radiological properties of bone during the dental mini-implants placement (ex-vivo experimental study). Wiadomości Lekarskie. https://doi.org/10.36740/wlek/212511
Vancouver
Mykhajlychenko BG, Humeniuk VO, Mochalov IO, Tukalo IV, Vakhrusheva TM, Bilichenko IO, et al. The influence of implant channel preparation technique on the mechanical and radiological properties of bone during the dental mini-implants placement (ex-vivo experimental study). Wiadomości Lekarskie. 2025. doi:10.36740/wlek/212511
BibTeX
@article{Mykhajlychenko2025,
author = {Mykhajlychenko, Bohdan G and Humeniuk, Vladyslav O and Mochalov, Iurii O and Tukalo, Ihor V and Vakhrusheva, Tetiana M and Bilichenko, Ihor O and Mochalov, Oleksandr O},
title = {The influence of implant channel preparation technique on the mechanical and radiological properties of bone during the dental mini-implants placement (ex-vivo experimental study)},
journal = {Wiadomości Lekarskie},
year = {2025},
doi = {10.36740/wlek/212511}
}
EUVIMED