EUVIMEDEUVIMED entdecken
Crossref

The influence of implant channel preparation technique on the mechanical and radiological properties of bone during the dental mini-implants placement (ex-vivo experimental study)

Bohdan G Mykhajlychenko, Vladyslav O Humeniuk, Iurii O Mochalov, Ihor V Tukalo, Tetiana M Vakhrusheva, Ihor O Bilichenko, Oleksandr O Mochalov

Wiadomości Lekarskie · 2025

DOI: 10.36740/wlek/212511 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Wiadomości Lekarskie, 2025. Verfasst von Bohdan G Mykhajlychenko und 6 weiteren Autor:innen. Beteiligte Einrichtung: NATIONAL UNIVERSITY OF HEALTH CARE OF UKRAINE NAMED BY P. L. SHUPIK, KYIV, UKRAINE. Hauptthemen laut MEDLINE: Dental Implants, Dental Implantation, Endosseous, Osteotomy, Ribs.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To compare the mechanical and radiological properties of animal bone after preparation with different surgical protocols (including tissue compaction/ densification) Materials and Methods: Samples of animal bone tissue (porcine ribs) were prepared according to 4 protocols: osteotomic, compaction with a bone condenser, slow (50 rpm) and osteocondensation without special burrs. After preparation, the torque was measured and relative radiological density of the bone was examined using CBCT.

Results

The torque when using the slow protocol (50 rpm) was 35.82 ± 5.10 N×cm (M = 36.48), with the standard osteotomic technique – 37.27 ± 2.14 N×cm (M = 37.40), with the bone condensors – 46.57 ± 2.72 N×cm (M = 46.75) and with osteodensification – 50.61 ± 6.77 N×cm (M = 50.16). The lowest relative x-ray density of the walls of the implantation channel was when using the osteotomy protocol (1000 rpm) – 372.85 ± 181.01 dHU (M = 374.00), with the slow protocol – 538.75 ± 167.82 dHU (M = 522.50). Slightly higher values were obtained with the use of bone condensors – 602.18±263.42 dHU (M = 549.00), and the highest was with osteodensification technique – 877.75±226.25 dHU (M = 862.50).

Conclusions

The use of bone condensors and osteodensification techniques (even without special burs) durin: the preparation of the implantation channel for mini-implants leads to progressive improvement of bone tissue.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsDental Implantation, EndosseousOsteotomyRibsAnimalsSwineTorqueCone-Beam Computed Tomography

Stichwörter der Autor:innen

bonedental implantationpreparation protocoltorquex-ray

Substanzen

Dental Implants

Autor:innen und Institutionen

  • NATIONAL UNIVERSITY OF HEALTH CARE OF UKRAINE NAMED BY P. L. SHUPIK, KYIV, UKRAINE.
  • UZHHOROD NATIONAL UNIVERSITY, UZHHOROD, UKRAINE.
  • OBUKHIV CITY DENTAL POLYCLINIC, OBUKHIV, UKRAINE.

Zitieren

APA

Mykhajlychenko, B. G., Humeniuk, V. O., Mochalov, I. O., Tukalo, I. V., Vakhrusheva, T. M., Bilichenko, I. O., & Mochalov, O. O. (2025). The influence of implant channel preparation technique on the mechanical and radiological properties of bone during the dental mini-implants placement (ex-vivo experimental study). Wiadomości Lekarskie. https://doi.org/10.36740/wlek/212511

Vancouver

Mykhajlychenko BG, Humeniuk VO, Mochalov IO, Tukalo IV, Vakhrusheva TM, Bilichenko IO, et al. The influence of implant channel preparation technique on the mechanical and radiological properties of bone during the dental mini-implants placement (ex-vivo experimental study). Wiadomości Lekarskie. 2025. doi:10.36740/wlek/212511

BibTeX
@article{Mykhajlychenko2025,
  author = {Mykhajlychenko, Bohdan G and Humeniuk, Vladyslav O and Mochalov, Iurii O and Tukalo, Ihor V and Vakhrusheva, Tetiana M and Bilichenko, Ihor O and Mochalov, Oleksandr O},
  title = {The influence of implant channel preparation technique on the mechanical and radiological properties of bone during the dental mini-implants placement (ex-vivo experimental study)},
  journal = {Wiadomości Lekarskie},
  year = {2025},
  doi = {10.36740/wlek/212511}
}
Kostenlos starten →