EUVIMEDOpdag EUVIMED
Klinische Studie

Optical Accuracy Assessment of Robotically Assisted Dental Implant Surgery for Partially Edentulous Patients: A Single-Arm Clinical Trial

Dmitriy Klass, Albert Price, Massimo DiBattista, Serge Dibart, Jeremy Kernitsky

The International Journal of Oral & Maxillofacial Implants · 2024

DOI: 10.11607/jomi.10592 ↗

At a glance

Klinische Studie in The International Journal of Oral & Maxillofacial Implants, 2024. Written by Dmitriy Klass and 4 co-authors. Major MEDLINE topics: Dental Implantation, Endosseous, Robotic Surgical Procedures, Jaw, Edentulous, Partially. Cited 8 times so far (Crossref).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

PURPOSE: To quantify the clinical accuracy of a robotically assisted implant guidance system in partially edentulous patients without the use of postoperative CBCT. MATERIALS AND METHODS: A total of 10 implants (7 patients) were placed in partially edentulous patients utilizing a robotically assisted implant guidance system. Following the implant placement, an intraoral scan was performed to register the implant position after attaching a scan body. The virtual plan and the postoperative intraoral scan with the scan bodies were exported as STL files and superimposed, and discrepancies were analyzed using Geomagic Control X software. Positional deviations were measured between the midpoint of the platform and apex of the planned and achieved implant positions. RESULTS: Seven of the 10 implants in this study were defined as fully robotically guided, while 3 were partially robotically guided. For the fully robotic dynamically guided group, the mean deviation at the midpoint of the restorative platform of the implant, the apex of the implant, the top of the scan body, and the mean angular deviation were 1.31 ± 0.46 mm, 1.58 ± 0.61 mm, 1.11 ± 0.57 mm, and 2.34 ± 1.71 degrees, respectively. For the partially robotic dynamically guided cases, these values were 1.31 ± 0.49 mm, 1.45 ± 0.3 mm, 1.74 ± 0.47 mm, and 3.75 ± 2.53 degrees, respectively. Eight of the 10 implants (irrespective of full or partial guidance) showed a buccal displacement. CONCLUSIONS: Robotic surgery offers a level of accuracy similar to fully guided implant placement, without the need for a physical template, and allows for changes in the surgical plan at any time. The analytical method described in this study is an effective and radiation-free quality-control tool that can be used in implant dentistry as well as in other areas of dental research.

Subjects

MeSH terms (MEDLINE)

Dental Implantation, EndosseousRobotic Surgical ProceduresJaw, Edentulous, PartiallyHumansMaleFemaleMiddle AgedSurgery, Computer-AssistedAdultDental ImplantsTreatment OutcomeCone-Beam Computed TomographyAged

Substances

Dental Implants

Cite

APA

Klass, D., Price, A., DiBattista, M., Dibart, S., & Kernitsky, J. (2024). Optical Accuracy Assessment of Robotically Assisted Dental Implant Surgery for Partially Edentulous Patients: A Single-Arm Clinical Trial. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.10592

Vancouver

Klass D, Price A, DiBattista M, Dibart S, Kernitsky J. Optical Accuracy Assessment of Robotically Assisted Dental Implant Surgery for Partially Edentulous Patients: A Single-Arm Clinical Trial. The International Journal of Oral & Maxillofacial Implants. 2024. doi:10.11607/jomi.10592

BibTeX
@article{Klass2024,
  author = {Klass, Dmitriy and Price, Albert and DiBattista, Massimo and Dibart, Serge and Kernitsky, Jeremy},
  title = {Optical Accuracy Assessment of Robotically Assisted Dental Implant Surgery for Partially Edentulous Patients: A Single-Arm Clinical Trial},
  journal = {The International Journal of Oral & Maxillofacial Implants},
  year = {2024},
  doi = {10.11607/jomi.10592}
}
Start for free →