Accuracy of a calibration method based on cone beam computed tomography and intraoral scanner data registration for robot-assisted implant placement: A single arm clinical study
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2025.10.017 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Yi Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: Graduate student, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Cli…. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Dental Implantation, Endosseous, Robotic Surgical Procedures, Surgery, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Beijing Natural Science Foundation, Natural Science Foundation of Beijing Municipality.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Robotic computer assisted implant surgery (r-CAIS) has evolved rapidly because of its enhanced precision and efficiency. Intraoperative patient positioning calibration is critical for ensuring r-CAIS accuracy. A calibration method based on cone beam computed tomography (CBCT) and intraoral scanner (IOS) data registration for robot-assisted implant placement has been proposed previously, and its accuracy validated in vitro; however, its in vivo performance remains unclear. PURPOSE: This single arm clinical study aimed to evaluate the clinical feasibility and accuracy of calibrating r-CAIS through CBCT and IOS data registration. MATERIAL AND METHODS: Ten participants with partial edentulism (1 to 3 missing teeth) were enrolled for robotic implant placement. A preoperative surgical plan was performed based on the CBCT scans. During implant surgery, the participant was scanned with an IOS, with patient positioning calibration accomplished through CBCT and IOS data registration. Implants were subsequently placed automatically via the robotic system according to the preoperative plan. Two weeks postoperatively, CBCT scans were obtained, and deviations between the planned and actual implant positions were measured by superimposing preoperative and postoperative CBCT data by using the robotic software program. The Shapiro-Wilk test was conducted to evaluate the normality of data. Quantitative variables were expressed as mean ±standard deviation, 95% confidence interval (CI), maximum, and minimum. RESULTS: Fifteen implants were autonomously placed in 10 participants by using r-CAIS technology. No intraoperative adverse events or postoperative complications occurred. By using the CBCT and IOS data registration approach, the autonomous robotic system achieved a mean ±standard deviation angular deviation of 1.46 ±0.48 degrees (95% CI: 1.23 to 1.71 degrees), with 3-dimensional deviations of 0.77 ±0.21 mm (95% CI: 0.65 to 0.87 mm) and 0.72 ±0.24 mm (95% CI: 0.61 to 0.84 mm) at the implant platform and apex, respectively. CONCLUSIONS: The CBCT and IOS data registration method for calibrating r-CAIS demonstrated clinically acceptable feasibility and accuracy in partially edentulous participants.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Graduate student, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Researc…
- Associate Professor, First Division, Peking University School and Hospital of Stomatology, Beijing, PR China.
- Professor, Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, PR China.
- Clinical Professor, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Resea…
Förderung
- Beijing Natural Science Foundation
- Natural Science Foundation of Beijing Municipality
Zitieren
APA
Li, Y., Liu, M., Tan, J., & Liu, D. X. (2025). Accuracy of a calibration method based on cone beam computed tomography and intraoral scanner data registration for robot-assisted implant placement: A single arm clinical study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.10.017
Vancouver
Li Y, Liu M, Tan J, Liu DX. Accuracy of a calibration method based on cone beam computed tomography and intraoral scanner data registration for robot-assisted implant placement: A single arm clinical study. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.10.017
BibTeX
@article{Li2025,
author = {Li, Yi and Liu, Mingyue and Tan, Jianguo and Liu, Dr Xiaoqiang},
title = {Accuracy of a calibration method based on cone beam computed tomography and intraoral scanner data registration for robot-assisted implant placement: A single arm clinical study},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2025.10.017}
}
EUVIMED