EUVIMEDOpdag EUVIMED
VergleichsstudieRandomisierte kontrollierte Studie

Comparison of the Effect of Implant Abutment Surface Modifications on the Retention of Implant-Supported Restorations

Mohammed Aatif Abid Khan, Aamir Zahid Godil, Sanaa Akhlaq Wadwan, Mohit Gurunath Kheur

The International Journal of Oral and Maxillofacial Implants · 2024-04 · 39 (2) · 278-285

DOI: 10.11607/jomi.10015 ↗

At a glance

Vergleichsstudie in The International Journal of Oral and Maxillofacial Implants, 2024-04. Written by Mohammed Aatif Abid Khan and 3 co-authors. Major MEDLINE topics: Dental Prosthesis, Implant-Supported, Surface Properties, Dental Abutments, Titanium. Cited 5 times so far (Crossref).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

PURPOSE: To evaluate and compare the difference in retention between implant-supported restorations with and without surface modification of the implant abutments. MATERIALS AND METHODS: A total of 30 patients with singletooth implants were restored with cement-retained (Multilink N, Ivoclar) restorations using titanium base abutments (Variobase, Straumann) and randomly assigned surface modifications. Group 1 used nonmodified abutments, group 2 used sandblasted abutments, and group 3 used sandblasted abutments followed by an application of metal primer. All patients were recalled for a baseline examination 6 months after crown placement. The pull-out strength and intergroup distribution of mean pull-out strength were assessed. To assess differences between the three groups, intergroup statistical comparison of continuous variables was done using one-way ANOVA with Tukey correction for multiple group comparisons. RESULTS: The results of the intergroup mean pull-out strength distribution revealed that the distribution of mean ± SD pull-out strength in group 1, group 2, and group 3 were 220.79 ± 94.23, 488.64 ± 84.12, and 705.46 ± 112.75 Ncm, respectively. CONCLUSIONS: Sandblasting followed by the application of metal primer produced the highest retention of porcelain-fused-to-metal (PFM) crowns to titanium base abutments, followed by sandblasting alone, with the least retention being observed with no surface treatment.

Subjects

MeSH terms (MEDLINE)

Dental Prosthesis, Implant-SupportedSurface PropertiesDental AbutmentsTitaniumDental Prosthesis RetentionDental Implant-Abutment DesignMethacrylatesHumansFemaleMaleMiddle AgedCrownsAdultDental Stress Analysis

Author keywords

Ti-base abutmentVariobase abutmentdental implantsmetal primerresin cementsandblastingsurface modificationtitanium base

Substances

TitaniumMetal PrimerMethacrylates

Cite

APA

Khan, M. A. A., Godil, A. Z., Wadwan, S. A., & Kheur, M. G. (2024). Comparison of the Effect of Implant Abutment Surface Modifications on the Retention of Implant-Supported Restorations. The International Journal of Oral and Maxillofacial Implants, 39(2), 278-285. https://doi.org/10.11607/jomi.10015

Vancouver

Khan MAA, Godil AZ, Wadwan SA, Kheur MG. Comparison of the Effect of Implant Abutment Surface Modifications on the Retention of Implant-Supported Restorations. The International Journal of Oral and Maxillofacial Implants. 2024;39(2):278-285. doi:10.11607/jomi.10015

BibTeX
@article{Khan2024,
  author = {Khan, Mohammed Aatif Abid and Godil, Aamir Zahid and Wadwan, Sanaa Akhlaq and Kheur, Mohit Gurunath},
  title = {Comparison of the Effect of Implant Abutment Surface Modifications on the Retention of Implant-Supported Restorations},
  journal = {The International Journal of Oral and Maxillofacial Implants},
  year = {2024},
  volume = {39},
  number = {2},
  pages = {278--285},
  doi = {10.11607/jomi.10015}
}