EUVIMEDOdkrijte EUVIMED
Crossref

The Influence of Seating Load on Internal and Marginal Fit of a Fixed Dental Prosthesis: An In Vitro Study

Hanna Josefsson, Anna Fridell, Anders Falk, Per Vult von Steyern

The International Journal of Prosthodontics · 2026-08 · 1-17

DOI: 10.11607/ijp.9517 ↗

At a glance

Journal article in The International Journal of Prosthodontics, 2026-08. Written by Hanna Josefsson and 3 co-authors.

PovzetekBibliografski podatkiCiteRelated studies

Abstract (original language)

PURPOSE: This study aimed to investigate how axial seating loads and shear loads influence the marginal and internal fit of a six-unit fixed dental prosthesis (FDP), using the replica technique. MATERIALS AND METHODS: Preparation for a six-unit FDP was made on plastic teeth, and a titanium FDP was constructed using CAD/CAM. A master epoxy cast of the abutment teeth was fabricated. The fit of the FDP was evaluated using the impression replica technique. Seating loads at 20, 35, 50, and 70 N in an axial direction and shear loads at 50 N were applied. The replicas were sectioned, and the silicone film representing cement gap was measured. RESULTS: The results showed that seating loads of 20 N gave the largest cement gaps, and seating loads of 35 N had a great range. At seating loads of 50 N, smaller cement gaps could be seen. When testing with 70 N the cement gaps did not become any smaller. Testing with shear loads resulted in larger cement gaps compared to testing without shearing at 50 and 70 N. CONCLUSIONS: Within the limitations of the present in-vitro study, the following conclusions can be drawn. Seating loads below 50 N are insufficient to provide an acceptable fit of a six-unit FDP, whereas seating loads exceeding 50 N do not markedly improve the fit. The presence of shear loads affects the fit negatively. Further studies are needed to evaluate whether the results are applicable on other prosthetic constructions and in clinical settings.

Cite

APA

Josefsson, H., Fridell, A., Falk, A., & Vult von Steyern, P. (2026). The Influence of Seating Load on Internal and Marginal Fit of a Fixed Dental Prosthesis: An In Vitro Study. The International Journal of Prosthodontics, 1-17. https://doi.org/10.11607/ijp.9517

Vancouver

Josefsson H, Fridell A, Falk A, Vult von Steyern P. The Influence of Seating Load on Internal and Marginal Fit of a Fixed Dental Prosthesis: An In Vitro Study. The International Journal of Prosthodontics. 2026:1-17. doi:10.11607/ijp.9517

BibTeX
@article{Josefsson2026,
  author = {Josefsson, Hanna and Fridell, Anna and Falk, Anders and Vult von Steyern, Per},
  title = {The Influence of Seating Load on Internal and Marginal Fit of a Fixed Dental Prosthesis: An In Vitro Study},
  journal = {The International Journal of Prosthodontics},
  year = {2026},
  pages = {1--17},
  doi = {10.11607/ijp.9517}
}
Start for free →