Influence of endocrown-retained fixed dental prosthesis design on marginal integrity and fracture resistance
The Journal of Advanced Prosthodontics · 2026 · 18 (3) · 167
DOI: 10.4047/jap.2026.18.3.167 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Advanced Prosthodontics, 2026. Verfasst von Rasha Sayed Asaad und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Fixed Prosthodontics, Faculty of Dentistry, Benha National University, Obour, Egypt. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
To investigate the effect of zirconia endocrown-retained fixed dental prosthesis (FDP) designs on marginal integrity and fracture resistance after thermomechanical aging, compared with full-coverage-retained FDPs. MATERIALS AND METHODS.Three extracted mandibular second premolars and second molars were randomly assigned to three abutment designs: full-coverage retainers (A), butt-joint endocrowns (B), and endocrowns with shoulder finish line and ferrule-like extensions (C).All teeth were prepared as abutments for three-unit zirconia FDPs replacing a missing mandibular first molar, and each FDP was duplicated into 12 epoxy resin models.High translucent zirconia FDPs were fabricated using Computer-Aided Design-Computer-Aided Manufacturing (CAD-CAM) and cemented using self-adhesive resin cement.Marginal gaps were measured under a stereomicroscope (× 35) before and after thermomechanical aging (1.2 × 10 5 cycles, 49 N, 5 -55°C).Fracture resistance was assessed after aging under compressive loading until failure, and failure mode was recorded.Data were analyzed using one-way ANOVA with post hoc tests (α = 0.05).RESULTS.All groups showed a significant increase in marginal gap after aging (P < .05).Group B had the smallest mean marginal gap before and after aging (P < .001).Group A exhibited the highest fracture resistance, significantly exceeding Groups B and C, with Group B showing the lowest values (P < .001).Failure mode analysis indicated that fractures were confined to the connector regions, mainly the distal connectors, with occlusal extension observed in Groups B and C. CONCLUSION.Abutment design significantly affected the zirconia endocrown-retained FDPs performance.Marginal gaps increased after thermomechanical aging, but remained within clinically acceptable limits.The butt-joint design demonstrated superior marginal adaptation, while the full-coverage design exhibited the highest fracture resistance, exceeding physiologic posterior masticatory forces.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Fixed Prosthodontics, Faculty of Dentistry, Benha National University, Obour, Egypt.
- Department of Fixed Prosthodontics, Faculty of Dentistry, October 6 University, Giza, Egypt.
ORCID-Profile: Rasha Sayed Asaad, Marwa Beleidy
Zitieren
APA
Asaad, R. S., & Beleidy, M. (2026). Influence of endocrown-retained fixed dental prosthesis design on marginal integrity and fracture resistance. The Journal of Advanced Prosthodontics, 18(3), 167. https://doi.org/10.4047/jap.2026.18.3.167
Vancouver
Asaad RS, Beleidy M. Influence of endocrown-retained fixed dental prosthesis design on marginal integrity and fracture resistance. The Journal of Advanced Prosthodontics. 2026;18(3):167. doi:10.4047/jap.2026.18.3.167
BibTeX
@article{Asaad2026,
author = {Asaad, Rasha Sayed and Beleidy, Marwa},
title = {Influence of endocrown-retained fixed dental prosthesis design on marginal integrity and fracture resistance},
journal = {The Journal of Advanced Prosthodontics},
year = {2026},
volume = {18},
number = {3},
pages = {167},
doi = {10.4047/jap.2026.18.3.167}
}
EUVIMED