Does the Build Orientation Parameter Affect the Fit of Fixed Partial Dentures Fabricated by Additive Manufacturing?

Elie E Daou

International Journal of Prosthodontics · 2024

DOI: 10.11607/ijp.8343 ↗

At a glance

Journal article in International Journal of Prosthodontics, 2024. Written by Elie E Daou. Major MEDLINE topics: Chromium Alloys, Computer-Aided Design. Cited 4 times so far (Crossref).

SantraukaSubjectsBibliografiniai duomenysCiteRelated studies

Abstract (original language)

PURPOSE: This in vitro study evaluated the adaptation of cobalt-chromium (Co-Cr) fixed dental prostheses (FDPs) fabricated by selective laser melting (SLM) with different build angles. MATERIALS AND METHODS: Maxillary right first premolars and first molars from a typodont were prepared with 1-mm chamfer, 2-mm occlusal reduction, and total taper of 8 degrees to receive three-unit FDPs. After framework design, data were sent to a laser machine, and 30 specimens were fabricated from Co-Cr metal powder by SLM. Specimens were assigned to three groups (n = 10 per group) with different build angles of 0 (A0), 30 (A30), and 45 (A45) degrees. Marginal and internal fit were evaluated. Results were compared among build orientation groups and abutments. Data were analyzed using the Levene test, t test, and analysis of variance (α = .05). RESULTS: A statistical difference was found between different angle groups (P = .015). At the abutment level, a significant difference was found in the gap values between build orientation groups for the molars (P = .048). Group A0 reported the smallest mean discrepancy values, and group A45 the highest. Statistical differences were found between group A45 and groups A0 (P < .001) and A30 (P < .024). CONCLUSIONS: The fit of printed metal FDPs was affected by the build orientation but remained clinically acceptable.

Subjects

MeSH terms (MEDLINE)

Chromium AlloysComputer-Aided DesignDental Marginal AdaptationCobaltChromiumDenture, Partial, FixedDental Prosthesis Design

Substances

Chromium AlloysCobaltChromium

Cite

APA

Daou, E. E. (2024). Does the Build Orientation Parameter Affect the Fit of Fixed Partial Dentures Fabricated by Additive Manufacturing?. International Journal of Prosthodontics. https://doi.org/10.11607/ijp.8343

Vancouver

Daou EE. Does the Build Orientation Parameter Affect the Fit of Fixed Partial Dentures Fabricated by Additive Manufacturing?. International Journal of Prosthodontics. 2024. doi:10.11607/ijp.8343

BibTeX
@article{Daou2024,
  author = {Daou, Elie E},
  title = {Does the Build Orientation Parameter Affect the Fit of Fixed Partial Dentures Fabricated by Additive Manufacturing?},
  journal = {International Journal of Prosthodontics},
  year = {2024},
  doi = {10.11607/ijp.8343}
}
Start for free →