EUVIMEDEUVIMED entdecken
Crossref

An in vitro study using confocal laser scanning microscopy to evaluate the marginal misfits of different implant‐supported frameworks

Bruna S H Tonin iD, Jing Fu, Raniel F Peixoto iD, Nicholas G Fischer iD, Regina M Fernandes, Patrícia A Curylofo, Maria da Gloria C de Mattos, Ana Paula Macedo iD, Rossana P de Almeida iD

Journal of Prosthodontics · 2025

DOI: 10.1111/jopr.13826 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontics, 2025. Verfasst von Bruna S H Tonin und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dental Material and Prosthesis, Ribeirão Preto School of Dentistry, University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil. Hauptthemen laut MEDLINE: Dental Prosthesis, Implant-Supported, Dental Marginal Adaptation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Fundação de Amparo à Pesquisa do Estado de São Paulo.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to develop and evaluate a simple, non‐destructive method for assessing the misfit and passivity of implant‐retained prostheses frameworks. Materials and Methods To simulate the rehabilitation of a mandible posterior partially edentulous area using 3‐unit screw‐retained frameworks supported by two implants were fabricated and divided into the following five groups ( n = 10 in each group): OP = one‐piece framework cast in Co‐Cr with the conventional method (control‐group); Co‐Cr frameworks sectioned and welded by laser (=LAS) or tungsten inert gas (=TIG); Co‐Cr CAD‐CAM = milled Co‐Cr framework; Zir CAD‐CAM = milled zirconia framework. The horizontal |X| and vertical |Y| misfits were measured using confocal laser scanning microscopy with one or both screws tightened. Data were analyzed by a two‐way ANOVA with repeated measures and Bonferroni correction ( α = 0.05).

Results

The greatest |X| misfit was observed in the OP group with both screws tightened (290 µm) and one screw tightened (388 and 340 µm). The conventional casting groups sectioned and welded by laser or TIG had lower mean values (235.35 µm, both screws tightened; and 275 µm, one screw tightened) than the OP framework. However, these values still exceeded those of the milled Co‐Cr and zirconia frameworks (190 and 216 µm with both screws tightened). Across all reading conditions, every framework subjected to testing consistently maintained vertical |Y| misfit levels below the threshold of 53 µm; however, the milled frameworks exhibited higher vertical misfits than the frameworks obtained by the conventional cast method.

Conclusions

The frameworks, whether cast and sectioned with laser welding or milled from Co‐Cr, exhibit improved marginal misfit and enhanced passive fit when compared to other fabrication methods. Additionally, the use of confocal laser scanning microscopy is highly effective for passivity and misfit analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Prosthesis, Implant-SupportedDental Marginal AdaptationMicroscopy, ConfocalIn Vitro TechniquesHumansComputer-Aided DesignZirconiumDental Prosthesis DesignChromium AlloysDental Implants

Stichwörter der Autor:innen

computer‐aided designcomputer‐aided manufacturingdental implantsdental prosthesisimplant‐supported dental prosthesisprosthesis fittingprosthodontics

Substanzen

Zirconiumzirconium oxideChromium AlloysDental Implants

Autor:innen und Institutionen

  • Department of Dental Material and Prosthesis, Ribeirão Preto School of Dentistry, University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil.
  • Department of Prosthodontics, The Affiliated Hospital of Qingdao University, School of Stomatology of Qingdao University, Qingdao, China.
  • Department of Restorative Dentistry, Faculty of Pharmacy, Dentistry and Nursing, Federal University of Ceará (UFC), Fortaleza, Ceará, Brazil.
  • Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota (UMN), Minneapolis, Minnesota, USA.

ORCID-Profile: Bruna S H Tonin, Raniel F Peixoto, Nicholas G Fischer, Ana Paula Macedo, Rossana P de Almeida

Förderung

  • Fundação de Amparo à Pesquisa do Estado de São Paulo

Zitieren

APA

Tonin, B. S. H., Fu, J., Peixoto, R. F., Fischer, N. G., Fernandes, R. M., Curylofo, P. A., de Mattos, M. D. G. C., Macedo, A. P., & de Almeida, R. P. (2025). An in vitro study using confocal laser scanning microscopy to evaluate the marginal misfits of different implant‐supported frameworks. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13826

Vancouver

Tonin BSH, Fu J, Peixoto RF, Fischer NG, Fernandes RM, Curylofo PA, et al. An in vitro study using confocal laser scanning microscopy to evaluate the marginal misfits of different implant‐supported frameworks. Journal of Prosthodontics. 2025. doi:10.1111/jopr.13826

BibTeX
@article{Tonin2025,
  author = {Tonin, Bruna S H and Fu, Jing and Peixoto, Raniel F and Fischer, Nicholas G and Fernandes, Regina M and Curylofo, Patrícia A and de Mattos, Maria da Gloria C and Macedo, Ana Paula and de Almeida, Rossana P},
  title = {An in vitro study using confocal laser scanning microscopy to evaluate the marginal misfits of different implant‐supported frameworks},
  journal = {Journal of Prosthodontics},
  year = {2025},
  doi = {10.1111/jopr.13826}
}
Kostenlos starten →