EFFECT OF LAB PROCEDURES AND ULTRASONIC-BATH CLEANING ON CUSTOMIZED IMPLANT ABUTMENT POLLUTION: AN IN VITRO STUDY

Deborah Roth, Philippe Compere, Dorien Van Hede, Marc Lamy, France Lambert

The International Journal of Prosthodontics · 2024

DOI: 10.11607/ijp.8328 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Prosthodontics, 2024. Verfasst von Deborah Roth und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Dental Abutments, Zirconium. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To validate the effectiveness of a simplified ultrasonic cleaning protocol to clean customized abutments, and to investigate the percentage of pollutants on customized abutments provided by the implant company and the additional effect of dental laboratory manipulations. MATERIALS AND METHODS: A total of 24 customized abutments were divided in two groups, 12 returning from the implant company and 12 others returning from the dental laboratory. In each group, there were 6 zirconia (Zr02) abutments and 6 .tanium (Ti) abutments. For each condition, half of the samples were cleaned with the experimental protocol, and the others were left as delivered by the company. The two-step cleaning protocol consisted of mechanical treatment with a sterile compress soaked in a detergent over the transgingival part of the abutment, followed by three successive ultrasound baths for two minutes/bath. The presence of pollutants was quantified using scanning electron microscopy. RESULTS: The suggested cleaning method allowed to significantly decrease the quantity of pollutants (P = .0006). The abutments returning from the dental laboratory were significantly more polluted than those coming directly from the implant company (P = .0043). The cleaning effect was highly significant in both groups (P < .0001). The quantity of pollutants before cleaning were similar in the titanium and in the zirconia groups and the cleaning effect was highly significant in both groups (P = .0009). CONCLUSIONS: The cleaning protocol tested was successful on the customized abutments from each group.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental AbutmentsZirconiumLaboratories, DentalIn Vitro TechniquesMicroscopy, Electron, ScanningUltrasonicsDental Implant-Abutment DesignHumansTitaniumEquipment Contamination

Substanzen

Zirconiumzirconium oxideTitanium

Zitieren

APA

Roth, D., Compere, P., Van Hede, D., Lamy, M., & Lambert, F. (2024). EFFECT OF LAB PROCEDURES AND ULTRASONIC-BATH CLEANING ON CUSTOMIZED IMPLANT ABUTMENT POLLUTION: AN IN VITRO STUDY. The International Journal of Prosthodontics. https://doi.org/10.11607/ijp.8328

Vancouver

Roth D, Compere P, Van Hede D, Lamy M, Lambert F. EFFECT OF LAB PROCEDURES AND ULTRASONIC-BATH CLEANING ON CUSTOMIZED IMPLANT ABUTMENT POLLUTION: AN IN VITRO STUDY. The International Journal of Prosthodontics. 2024. doi:10.11607/ijp.8328

BibTeX
@article{Roth2024,
  author = {Roth, Deborah and Compere, Philippe and Van Hede, Dorien and Lamy, Marc and Lambert, France},
  title = {EFFECT OF LAB PROCEDURES AND ULTRASONIC-BATH CLEANING ON CUSTOMIZED IMPLANT ABUTMENT POLLUTION: AN IN VITRO STUDY},
  journal = {The International Journal of Prosthodontics},
  year = {2024},
  doi = {10.11607/ijp.8328}
}