Mechanical stability of posterior implant‐supported monolithic zirconia cantilever on titanium‐base abutments. An in vitro study
Clinical Oral Implants Research · 2024
DOI: 10.1111/clr.14251 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Implants Research, 2024. Verfasst von Carme Riera und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland. Hauptthemen laut MEDLINE: Zirconium, Titanium, Dental Prosthesis, Implant-Supported, Dental Abutments. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Oral Reconstruction Foundation.
Abstract (Originalsprache)
Purpose
Investigate survival and technical complications of two‐unit posterior implant‐supported cantilever made of monolithic zirconia on titanium‐base abutments (Zr‐TiB) vs. porcelain‐fused‐to‐metal on castable gold abutments (PFM‐GA) using two different implant connections, internal butt‐joint (IBJ) and internal conical (IC). Materials and Methods Forty‐eight implants (4.3 mm diameter) were divided into four groups ( n = 12) to support 2‐unit mandibular premolar cantilevers with two different materials (Zr‐TiB vs. PFM‐GA) and two connection types (IBJ vs. IC). Tested groups were as follows: (1) IBJ/Zr‐TiB; (2) IBJ/PFM‐GA; (3) IC/Zr‐TiB; and (4) IC/PFM‐GA. Specimens were thermomechanical aged (1,200,000 cycles, 98 N, 5–55°C) with occlusal axial load on the pontic. Catastrophic and non‐catastrophic events were registered, and removal torque values measured before and after aging. Specimens surviving aging were subjected to loading until failure. Survival, total complication rates, torque loss (%), and bending moments were calculated.
Results
From 48 specimens, 38 survived aging. Survival rates significantly varied from 16.7% (IC/PFM‐GA) to 100% (IBJ/Zr‐TiB; IBJ/PFM‐GA; IC/Zr‐TiB) ( p < .01). Internal conical connection revealed significantly higher torque loss (IC/ZrTiB – 67%) compared to internal butt‐joint (IBJ/Zr‐TiB – 44%; IBJ/PFM‐GA – 46%) ( p < .01). Bending moments were higher in internal butt‐joint connections than in internal conical ( p < .05). Conclusion and Clinical Implications Two‐unit posterior implant‐supported cantilever FDPs replacing mandibular premolars composed of monolithic zirconia on titanium‐base abutments demonstrated higher mechanical stability compared to porcelain‐fused‐to‐metal on castable gold abutments in this in vitro study. The internal conical connection combined with porcelain‐fused‐to‐metal on gold abutments revealed a high number of failures; therefore, their clinical use may be considered cautiously for this indication.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
ORCID-Profile: Carme Riera, Duygu Karasan, Irena Sailer, João Pitta
Förderung
- Oral Reconstruction Foundation
Zitieren
APA
Riera, C., Karasan, D., Sailer, I., Mojon, P., Fehmer, V., & Pitta, J. (2024). Mechanical stability of posterior implant‐supported monolithic zirconia cantilever on titanium‐base abutments. An in vitro study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14251
Vancouver
Riera C, Karasan D, Sailer I, Mojon P, Fehmer V, Pitta J. Mechanical stability of posterior implant‐supported monolithic zirconia cantilever on titanium‐base abutments. An in vitro study. Clinical Oral Implants Research. 2024. doi:10.1111/clr.14251
BibTeX
@article{Riera2024,
author = {Riera, Carme and Karasan, Duygu and Sailer, Irena and Mojon, Phillipe and Fehmer, Vincent and Pitta, João},
title = {Mechanical stability of posterior implant‐supported monolithic zirconia cantilever on titanium‐base abutments. An in vitro study},
journal = {Clinical Oral Implants Research},
year = {2024},
doi = {10.1111/clr.14251}
}
EUVIMED