Comparison of Heat Transfer Through Various Fixed Prosthetic Materials During Grinding
The International Journal of Prosthodontics · 2024
DOI: 10.11607/ijp.8292 ↗At a glance
Vergleichsstudie in The International Journal of Prosthodontics, 2024. Written by Burcu Bal and 3 co-authors. Major MEDLINE topics: Zirconium, Hot Temperature, Ceramics, Materials Testing. Cited 1 times so far (Crossref).
Abstract (original language)
PURPOSE: To measure and compare the mean temperature values due to heat generated during the grinding of different prosthetic materials with diamond burs using a high-speed instrument with and without water cooling. MATERIALS AND METHODS: In total, 120 disk-shaped specimens (10 × 2 mm), each with a smaller disk in the center (3 × 2 mm), were fabricated from yttrium-stabilized zirconia, monolithic zirconia, glass-ceramic, indirect composite, polyetheretherketone (PEEK), and cast metal (Ni-Cr alloy). The specimens were divided into six groups (n = 20) according to material type. The specimens in each group were ground continuously with a high-speed handpiece and diamond burs with (n = 10) and without (n = 10) water cooling until the smaller disks were removed. Two different methods (thermocouple and thermal camera) were used to measure the temperature during the grinding process. Results were analyzed using two-way ANOVA and paired-samples t test (P < .05). RESULTS: PEEK had the lowest mean temperature and metal had the highest values, both with and without water cooling, according to data measured with a thermocouple. Zirconia and monolithic zirconia samples without water cooling had the highest mean temperature when measured with a thermal camera. Both with and without water cooling, composite samples had the lowest mean temperatures for thermal camera measurements. CONCLUSIONS: Water cooling is strongly recommended when grinding all prosthetic materials. The heat transferred to the supporting teeth may depend on the thermal conductivity of the material used.
Subjects
MeSH terms (MEDLINE)
Substances
Cite
APA
Bal, B., Erkul, S., Ozkurt-Kayahan, Z., & Kazazoglu, E. (2024). Comparison of Heat Transfer Through Various Fixed Prosthetic Materials During Grinding. The International Journal of Prosthodontics. https://doi.org/10.11607/ijp.8292
Vancouver
Bal B, Erkul S, Ozkurt-Kayahan Z, Kazazoglu E. Comparison of Heat Transfer Through Various Fixed Prosthetic Materials During Grinding. The International Journal of Prosthodontics. 2024. doi:10.11607/ijp.8292
BibTeX
@article{Bal2024,
author = {Bal, Burcu and Erkul, Selen and Ozkurt-Kayahan, Zeynep and Kazazoglu, Ender},
title = {Comparison of Heat Transfer Through Various Fixed Prosthetic Materials During Grinding},
journal = {The International Journal of Prosthodontics},
year = {2024},
doi = {10.11607/ijp.8292}
}
EUVIMED