EUVIMEDEUVIMED entdecken
Crossref

Marginal Fit and Internal Adaptation of Monolithic Zirconia 3-Unit Fixed Dental Prosthesis: In Vitro Study

Nuha A Alkaff, Dorin N Ruse, Kevin Aminzadeh, Alan G Hannam, Nesrine Mostafa

The International Journal of Prosthodontics · 2024

DOI: 10.11607/ijp.8087 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Prosthodontics, 2024. Verfasst von Nuha A Alkaff und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Dental Prosthesis Design, Dental Prosthesis.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To compare the marginal and internal fit of monolithic zirconia (MZ) 3-unit fixed dental prostheses (FDPs) fabricated using two CAD/CAM workflows: full-chairside (FCH) and lab (LAB). MATERIALS AND METHODS: The right maxillary first premolar and first molar were prepared for MZ 3-unit FDPs on a typodont. CEREC Primescan digitized the typodont model 15 Omes. A total of 30 FDPs was fabricated using two processes: FCH (n = 15) and LAB (n = 15). FCH and LAB FDPs were designed using CEREC SW 4.5.1 and Exocad and milled using CEREC MC X and Zirkonzhan 600/V3, respectively. A fast-sintering protocol was used in both groups. A dual-scan technique was used to assess the cement space at the occlusal surface (OC), axial wall (AX), and margin (MA). Statistical analysis of the results was performed using univariate ANOVA with Scheff. post hoc test (a = .05). RESULTS: Measurements in the FCH and LAB groups were within the clinically acceptable marginal and internal fit. The fit of FCH FDPs at MA, AX, and OC was 77.50 ± 29.99 μm, 99.67 ± 21.58 μm, and 150.03 ± 30.78 μm, respectively. The fit of LAB FDPs at MA, AX, and OC was 100.27 ± 27.06 μm, 116.53 ± 17.90 μm, and 142.30 ± 19.00 μm, respectively. The difference between the two groups was not statistically significant. CONCLUSIONS: MZ 3-unit FDPs fabricated using FCH have clinically acceptable marginal and internal fit. This result verifies the ability of FCH workflow to fabricate MZ mulOunit FDPs in a single visit.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Prosthesis DesignDental ProsthesisDental Marginal AdaptationZirconiumDental CementsComputer-Aided Design

Substanzen

zirconium oxideZirconiumDental Cements

Zitieren

APA

Alkaff, N. A., Ruse, D. N., Aminzadeh, K., Hannam, A. G., & Mostafa, N. (2024). Marginal Fit and Internal Adaptation of Monolithic Zirconia 3-Unit Fixed Dental Prosthesis: In Vitro Study. The International Journal of Prosthodontics. https://doi.org/10.11607/ijp.8087

Vancouver

Alkaff NA, Ruse DN, Aminzadeh K, Hannam AG, Mostafa N. Marginal Fit and Internal Adaptation of Monolithic Zirconia 3-Unit Fixed Dental Prosthesis: In Vitro Study. The International Journal of Prosthodontics. 2024. doi:10.11607/ijp.8087

BibTeX
@article{Alkaff2024,
  author = {Alkaff, Nuha A and Ruse, Dorin N and Aminzadeh, Kevin and Hannam, Alan G and Mostafa, Nesrine},
  title = {Marginal Fit and Internal Adaptation of Monolithic Zirconia 3-Unit Fixed Dental Prosthesis: In Vitro Study},
  journal = {The International Journal of Prosthodontics},
  year = {2024},
  doi = {10.11607/ijp.8087}
}
Kostenlos starten →