EUVIMEDDécouvrir EUVIMED
Crossref

Passive Fit Analysis of Laser-Sintered, Three-Unit Implant Prostheses: An In Vitro Study

Stefano Del Monte, Shakeel Shahdad, Phil Taylor

International Journal of Prosthodontics · 2023

DOI: 10.11607/ijp.7261 ↗

At a glance

Journal article in International Journal of Prosthodontics, 2023. Written by Stefano Del Monte and 2 co-authors. Major MEDLINE topics: Dental Implants. Cited 1 times so far (Crossref).

RésuméSubjectsRéférences bibliographiquesCiteRelated studies

Abstract (original language)

PURPOSE: To assess if the implant-retained prostheses produced with laser-sintering technique present an accuracy and passive fit comparable to their milled counterpart. MATERIALS AND METHODS: Two regular neck Straumann analogs were placed in a block of PMMA 15 mm apart and parallel to each other. The PMMA block was then scanned and two groups of cobalt-chromium, screw-retained, three-unit implant prostheses were fabricated using milling (control) and laser-sintering (test) techniques. The prostheses were then screwed on the PMMA block and the vertical marginal gap between the prostheses and the analogs at the implant-abutment junction was measured twice, (1) when only one screw was tightened, and (2) when both screws were fully tightened. The average of each marginal gap measurement was compared to assess the difference in term of passive fit between the laser-sintered and the milled prostheses. RESULTS: The mean marginal gap of the milled and the laser-sintered groups were 23.18 µm (SD = 6.2) and 23.71 µm (SD = 19.5) respectively. CONCLUSIONS: Laser-sintered prostheses presented a marginal fit comparable to their milled counterpart and represent a clinically valid alternative to their milled counterpart. Int J Prosthodont 2023;36:e53-e60.

Subjects

MeSH terms (MEDLINE)

Dental ImplantsPolymethyl MethacrylateDental Marginal AdaptationComputer-Aided DesignDental Prosthesis, Implant-SupportedLasers

Substances

Dental ImplantsPolymethyl Methacrylate

Cite

APA

Del Monte, S., Shahdad, S., & Taylor, P. (2023). Passive Fit Analysis of Laser-Sintered, Three-Unit Implant Prostheses: An In Vitro Study. International Journal of Prosthodontics. https://doi.org/10.11607/ijp.7261

Vancouver

Del Monte S, Shahdad S, Taylor P. Passive Fit Analysis of Laser-Sintered, Three-Unit Implant Prostheses: An In Vitro Study. International Journal of Prosthodontics. 2023. doi:10.11607/ijp.7261

BibTeX
@article{DelMonte2023,
  author = {Del Monte, Stefano and Shahdad, Shakeel and Taylor, Phil},
  title = {Passive Fit Analysis of Laser-Sintered, Three-Unit Implant Prostheses: An In Vitro Study},
  journal = {International Journal of Prosthodontics},
  year = {2023},
  doi = {10.11607/ijp.7261}
}
Start for free →