EUVIMEDEUVIMED entdecken
Crossref

Effects of repeated milling with a 1 mm small-diameter cutting tool on tool dimensions and on the surface characteristics and marginal adaptation of zirconia implant-supported restorations

Yi-Ting Teng, Chia-Yuan Hu, Wei-Chen Lee, Tsung-Chieh Yang

The Journal of Prosthetic Dentistry · 2026-07 · 136 (1) · e335-e343

DOI: 10.1016/j.prosdent.2026.01.020 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-07. Verfasst von Yi-Ting Teng und 3 weiteren Autor:innen. Beteiligte Einrichtung: Graduate student, Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University and National Taiwan University Hospital, …. Hauptthemen laut MEDLINE: Zirconium, Computer-Aided Design, Dental Marginal Adaptation, Dental Prosthesis, Implant-Supported. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: National Taiwan University Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Limited information is available regarding the accuracy of computer-aided design and computer-aided manufacturing (CAD-CAM) zirconia implant-supported restorations in relation to tool wear under standardized repeated milling conditions. PURPOSE: The purpose of this in vitro study was to evaluate the correlations of milling tool wear with changes in tool morphology and the external surface characteristics and marginal adaptation of zirconia implant restorations during repeated milling cycles. MATERIAL AND METHODS: A mandibular premolar implant-supported restoration was designed using a CAD software program. Zirconia restorations were repeatedly milled with a Ø1-mm cutting tool until 1 additional specimen was fabricated after the software program indicated tool replacement. Tool deterioration was quantified, and the cutting edge width measured 0.2 mm from the tool tip for each cycle. Pre- and post-processing scans of each restoration were superimposed with a surface-matching program to calculate deviations. Marginal discrepancies between the zirconia restoration and implant abutment were assessed by image analysis. The Kruskal-Wallis test was used for statistical comparisons; Spearman correlation coefficients (ρ) were calculated to assess relationships between tool wear and test variables (α=.05). RESULTS: Progressive wear was observed on the milling tools. The cutting-edge width increased from 776.4 µm at 0% to 20% deterioration to 797.5 µm at 81% to 100% deterioration, indicating a strong correlation (r=.802). Digital superimposition revealed slight increases in surface deviations of the zirconia restorations with successive milling cycles. Marginal discrepancies substantially increased: horizontal gaps rose from 17.9 µm at 0% to 20% deterioration to 52.3 µm at 81% to 100% deterioration, also indicating a strong correlation (r=.664). CONCLUSIONS: As milling cycles increased, tools became progressively wider and blunter. Although the external surfaces of zirconia implant-supported restorations remained largely consistent, marginal discrepancies increased significantly.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ZirconiumComputer-Aided DesignDental Marginal AdaptationDental Prosthesis, Implant-SupportedDental Prosthesis DesignDental MaterialsDental ImplantsSurface PropertiesHumansImage Processing, Computer-Assisted

Substanzen

Zirconiumzirconium oxideDental MaterialsDental Implants

Autor:innen und Institutionen

  • Graduate student, Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University and National Taiwan University Hospital, Taipei, Taiwan, ROC.
  • Visiting Staff, National Taiwan University Hospital, Taipei, Taiwan, ROC.
  • Professor, Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan, ROC.
  • Associate Professor, School of Dentistry, National Taiwan University and National Taiwan University Hospital, Taipei, Taiwan, ROC. Electronic address: yangtc@ntu.edu.tw.

Förderung

  • National Taiwan University Hospital

Zitieren

APA

Teng, Y. T., Hu, C. Y., Lee, W. C., & Yang, T. C. (2026). Effects of repeated milling with a 1 mm small-diameter cutting tool on tool dimensions and on the surface characteristics and marginal adaptation of zirconia implant-supported restorations. The Journal of Prosthetic Dentistry, 136(1), e335-e343. https://doi.org/10.1016/j.prosdent.2026.01.020

Vancouver

Teng YT, Hu CY, Lee WC, Yang TC. Effects of repeated milling with a 1 mm small-diameter cutting tool on tool dimensions and on the surface characteristics and marginal adaptation of zirconia implant-supported restorations. The Journal of Prosthetic Dentistry. 2026;136(1):e335-e343. doi:10.1016/j.prosdent.2026.01.020

BibTeX
@article{Teng2026,
  author = {Teng, Yi-Ting and Hu, Chia-Yuan and Lee, Wei-Chen and Yang, Tsung-Chieh},
  title = {Effects of repeated milling with a 1 mm small-diameter cutting tool on tool dimensions and on the surface characteristics and marginal adaptation of zirconia implant-supported restorations},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  volume = {136},
  number = {1},
  pages = {e335--e343},
  doi = {10.1016/j.prosdent.2026.01.020}
}
Kostenlos starten →