EUVIMEDEUVIMED entdecken
Open Access

Wireless, customizable coaxially shielded coils for magnetic resonance imaging

Ke Wu iD, Xia Zhu, Stephan W Anderson iD, Xin Zhang iD

Science Advances · 14.06.2024 · 10 (24)

DOI: 10.1126/sciadv.adn5195 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Science Advances, erschienen am 14.06.2024. Verfasst von Ke Wu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Boston University, Boston, MA 02215, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Wireless Technology. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Anatomy-specific radio frequency receive coil arrays routinely adopted in magnetic resonance imaging (MRI) for signal acquisition are commonly burdened by their bulky, fixed, and rigid configurations, which may impose patient discomfort, bothersome positioning, and suboptimal sensitivity in certain situations. Herein, leveraging coaxial cables’ inherent flexibility and electric field confining property, we present wireless, ultralightweight, coaxially shielded, passive detuning MRI coils achieving a signal-to-noise ratio comparable to or surpassing that of commercially available cutting-edge receive coil arrays with the potential for improved patient comfort, ease of implementation, and substantially reduced costs. The proposed coils demonstrate versatility by functioning both independently in form-fitting configurations, closely adapting to relatively small anatomical sites, and collectively by inductively coupling together as metamaterials, allowing for extension of the field of view of their coverage to encompass larger anatomical regions without compromising coil sensitivity. The wireless, coaxially shielded MRI coils reported herein pave the way toward next-generation MRI coils.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingWireless TechnologyHumansEquipment DesignSignal-To-Noise RatioPhantoms, Imaging

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Boston University, Boston, MA 02215, USA.
  • Photonics Center, Boston University, Boston, MA 02215, USA.
  • Boston University Chobanian and Avedisian School of Medicine, Boston, MA 02118, USA.

ORCID-Profile: Ke Wu, Stephan W Anderson, Xin Zhang

Zitieren

APA

Wu, K., Zhu, X., Anderson, S. W., & Zhang, X. (2024). Wireless, customizable coaxially shielded coils for magnetic resonance imaging. Science Advances, 10(24). https://doi.org/10.1126/sciadv.adn5195

Vancouver

Wu K, Zhu X, Anderson SW, Zhang X. Wireless, customizable coaxially shielded coils for magnetic resonance imaging. Science Advances. 2024;10(24). doi:10.1126/sciadv.adn5195

BibTeX
@article{Wu2024,
  author = {Wu, Ke and Zhu, Xia and Anderson, Stephan W and Zhang, Xin},
  title = {Wireless, customizable coaxially shielded coils for magnetic resonance imaging},
  journal = {Science Advances},
  year = {2024},
  volume = {10},
  number = {24},
  doi = {10.1126/sciadv.adn5195}
}
Kostenlos starten →