EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Detunable wireless ladder resonator inserts for enhanced SNR of local array coil at 1.5T MRI

Ming Lu, Ruilin Wang, Yuanyuan Chen, Rangsong Li, Xiaoyue Yang, Hao Liang, Haoqin Zhu, Xinqiang Yan

Medical Physics · 2025

DOI: 10.1002/mp.17731 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2025. Verfasst von Ming Lu und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Nuclear Equipment and Nuclear Engineering, Yantai University, Yantai, Shandong, China. Hauptthemen laut MEDLINE: Signal-To-Noise Ratio, Magnetic Resonance Imaging, Wireless Technology. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Natural Science Foundation of Hefei Anhui Province of China, Graduate Innovation Foundation of Yantai University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Magnetic resonance imaging (MRI) is a non‐invasive technique that produces high‐resolution images with excellent soft‐tissue contrast, crucial for diagnosing various medical conditions. A key factor in MRI quality is the signal‐to‐noise ratio (SNR), which directly affects image clarity. To enhance SNR, passive inserts like high‐permittivity dielectric pads or metamaterials are used between the tissue and coil. However, this method faces challenges such as detuning during radiofrequency (RF) transmission, which can interfere with the transmit field ( B 1 + ) and pose safety issues.

Purpose

This study proposes a novel method to enhance SNR in MRI by using a non‐closed lumped‐element ladder resonator as a wireless insert. The aim is to optimize this ladder resonator through simulations and validate its performance in both phantom and in vivo MRI experiments.

Methods

The ladder resonator was designed and optimized through electromagnetic (EM) and RF circuit simulations using Ansys HFSS software. Various configurations (4, 6, 8, and 10 rungs) were tested. The optimized 8‐rung resonator was then fabricated and evaluated against a single‐loop resonator of the same size. MRI experiments were conducted using a 1.5T Siemens MRI scanner, assessing SNR improvements in both phantoms and volunteers.

Results

Simulation results indicated that the ladder resonator significantly improved local SNR compared to the single‐loop resonator. The 8‐rung ladder resonator provided the best performance. Experimental results corroborated these findings, with the 8‐rung ladder resonator showing SNR improvements up to 4.7 times in human head images, compared to the standard head array alone.

Conclusions

The study demonstrates that wireless ladder resonators can significantly enhance SNR in MRI, offering superior performance and more uniform sensitivity compared to traditional single‐loop designs. The detunable feature of the ladder resonator ensures it does not interfere with the RF field, making it suitable for routine clinical use. The simplicity, cost‐effectiveness, and compatibility with various MRI platforms underscore its potential for widespread clinical adoption.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Signal-To-Noise RatioMagnetic Resonance ImagingWireless TechnologyPhantoms, ImagingHumansEquipment DesignRadio Waves

Stichwörter der Autor:innen

MRIRF coilSNRladder resonatorwireless resonator

Autor:innen und Institutionen

  • College of Nuclear Equipment and Nuclear Engineering, Yantai University, Yantai, Shandong, China.
  • Sino Canada Health Engineering Research Institute (Hefei) Ltd., Hefei, Anhui, China.
  • Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, Tennessee, USA.
  • Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Sino Canada Health Institute Inc., Winnipeg, Manitoba, Canada.

Förderung

  • Natural Science Foundation of Hefei Anhui Province of China
  • Graduate Innovation Foundation of Yantai University

Zitieren

APA

Lu, M., Wang, R., Chen, Y., Li, R., Yang, X., Liang, H., Zhu, H., & Yan, X. (2025). Detunable wireless ladder resonator inserts for enhanced SNR of local array coil at 1.5T MRI. Medical Physics. https://doi.org/10.1002/mp.17731

Vancouver

Lu M, Wang R, Chen Y, Li R, Yang X, Liang H, et al. Detunable wireless ladder resonator inserts for enhanced SNR of local array coil at 1.5T MRI. Medical Physics. 2025. doi:10.1002/mp.17731

BibTeX
@article{Lu2025,
  author = {Lu, Ming and Wang, Ruilin and Chen, Yuanyuan and Li, Rangsong and Yang, Xiaoyue and Liang, Hao and Zhu, Haoqin and Yan, Xinqiang},
  title = {Detunable wireless ladder resonator inserts for enhanced SNR of local array coil at 1.5T MRI},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17731}
}
Kostenlos starten →