EUVIMEDEUVIMED entdecken
Vergleichsstudie

Detunable wireless resonator arrays for TMJ MRI: A comparative study

Haoqin Zhu, Qiang Zhang, Rangsong Li, Yuanyuan Chen, Gong Zhang, Ruilin Wang, Ming Lu, Xinqiang Yan

Magnetic Resonance Imaging · 2024

DOI: 10.1016/j.mri.2024.04.016 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Haoqin Zhu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Sino Canada Health Institute Inc., Winnipeg, Manitoba, Canada. Electronic address: hzhu@taumedis.ca. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Signal-To-Noise Ratio, Wireless Technology, Temporomandibular Joint. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Temporomandibular Joint Magnetic Resonance Imaging (TMJ MRI) is crucial for diagnosing temporomandibular disorders (TMDs). This study advances the use of inductively coupled wireless coils to enhance imaging quality in TMJ MRI. After investigating multiple wireless resonator configurations, including a 1-loop design with a loop diameter of 9 cm, a 2-loop design with each loop having a diameter of 7 cm, and a 3-loop design with each loop having a diameter of 5 cm, our findings indicate that the 3-loop configuration achieves the optimal signal-to-noise ratio (SNR), surpassing other wireless arrays. Bilateral deployment of wireless coils further amplifies SNR, enabling superior visualization of TMJ structures, particularly with the 3-loop design. This cost-effective and comfortable solution, featuring a detunable design, eliminates the need for system parameter adjustments. The study indicates broad adaptability across MRI platforms, enhancing TMJ imaging for routine clinical diagnostics of TMDs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingSignal-To-Noise RatioWireless TechnologyTemporomandibular JointEquipment DesignHumansPhantoms, ImagingTemporomandibular Joint Disorders

Stichwörter der Autor:innen

ArrayDetuneMRIRF coilTMJWireless coil

Autor:innen und Institutionen

  • Sino Canada Health Institute Inc., Winnipeg, Manitoba, Canada. Electronic address: hzhu@taumedis.ca.
  • The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia 010010, China.
  • Sino Canada Health Engineering Research Institute (Hefei) Ltd. Hefei, Anhui 230088, China.
  • Hubei Key Laboratory of Intelligent Conveying Technology and Device, Hubei Polytechnic University, China.
  • College of Nuclear Equipment and Nuclear Engineering, Yantai University, Yantai, Shandong, China.
  • Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN…

Zitieren

APA

Zhu, H., Zhang, Q., Li, R., Chen, Y., Zhang, G., Wang, R., Lu, M., & Yan, X. (2024). Detunable wireless resonator arrays for TMJ MRI: A comparative study. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.04.016

Vancouver

Zhu H, Zhang Q, Li R, Chen Y, Zhang G, Wang R, et al. Detunable wireless resonator arrays for TMJ MRI: A comparative study. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.04.016

BibTeX
@article{Zhu2024,
  author = {Zhu, Haoqin and Zhang, Qiang and Li, Rangsong and Chen, Yuanyuan and Zhang, Gong and Wang, Ruilin and Lu, Ming and Yan, Xinqiang},
  title = {Detunable wireless resonator arrays for TMJ MRI: A comparative study},
  journal = {Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1016/j.mri.2024.04.016}
}
Kostenlos starten →