Flexible and wireless metasurface coils for knee and elbow MRI
European Radiology Experimental · 2025
DOI: 10.1186/s41747-024-00549-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Radiology Experimental, 2025. Verfasst von Daniel M Düx und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany. duex.daniel@mh-hannover.de. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Elbow, Knee, Wireless Technology. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundesministerium für Bildung, Wissenschaft, Forschung und Technologie.
Abstract (Originalsprache)
Background
Metasurface coils (MCs) are a promising magnetic resonance imaging (MRI) technology. Aiming to evaluate the image quality of MCs for knee and elbow imaging, we compared signal-to-noise ratio (SNRs) obtained in standard clinical setups.
Methods
Knee and elbow MRI routine sequences were applied at 1.5 T, implementing four coil scenarios: (1) 15-channel transmit/receive knee coil; (2) four-channel multipurpose coil (flex coil); (3) MC + spine coil; and (4) MC + multipurpose coil. Three regions of interest (ROIs) at different anatomical depths were compared.
Results
Seven participants (aged 28 ± 2 years; 6 males) were enrolled. In elbow MRI, the MC + spine coil demonstrated the highest SNR across all ROIs (superficial-anterior: +114%, p = 0.008; middle: +147%, p = 0.008; deep-posterior: +24%, p = 0.039) compared to the flex coil and all ROIs, except the deepest from the MC, compared to the knee coil (superficial-anterior: +28%, p = 0.016; middle: +104%, p = 0.008; deep-posterior: −1%, p = 0.531). In knee MRI, the MC + spine coil provided higher SNR compared to the flex coil, except posterior (superficial-anterior: +69%, p = 0.008; middle: +288%, p = 0.008; deep-posterior: −12%, p = 0.148) versus the knee coil, the MC + spine coil was superior in the middle but non-different in superficial pre-patellar areas and less in deep-posterior areas (superficial-anterior: −8%, p = 0.188; middle: +44%, p = 0.008; deep-posterior: −36%, p = 0.016).
Conclusion
Wireless MCs exhibited great potential for knee and elbow MRI outperforming the flex coil. Future developments will improve the posterior illumination to increase its clinical value. Relevance statement MCs offer enhanced versatility, flexibility, and patient comfort. If universal MC designs can achieve image quality comparable to those of standard coils and simultaneously be utilized across multiple body areas, the technology may revolutionize future musculoskeletal MRIs. Key Points MCs are promising in MRI, but homogeneity is challenging depending on the design. Signal-to-noise-ratio was improved for knee and elbow imaging with slight inhomogeneous illumination. MCs could match the image quality of standard coils in both knee and elbow imaging. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany. duex.daniel@mh-hannover.de.
- Research Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany. duex.daniel@mh-hannover.de.
- Research Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany.
- Microwave and Communication Engineering, Otto-von-Guericke University, Magdeburg, Germany.
- Department Biomedical Magnetic Resonance, Otto-von-Guericke University, Magdeburg, Germany.
- Department of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.
Förderung
- Bundesministerium für Bildung, Wissenschaft, Forschung und Technologie
Zitieren
APA
Düx, D. M., Kowal, R., Knull, L., Schröer, S., Belker, O., Horstmann, D., Gutt, M., Maune, H., Speck, O., Wacker, F., Hensen, B., & Gutberlet, M. (2025). Flexible and wireless metasurface coils for knee and elbow MRI. European Radiology Experimental. https://doi.org/10.1186/s41747-024-00549-8
Vancouver
Düx DM, Kowal R, Knull L, Schröer S, Belker O, Horstmann D, et al. Flexible and wireless metasurface coils for knee and elbow MRI. European Radiology Experimental. 2025. doi:10.1186/s41747-024-00549-8
BibTeX
@article{Dx2025,
author = {Düx, Daniel M and Kowal, Robert and Knull, Lucas and Schröer, Simon and Belker, Othmar and Horstmann, Dominik and Gutt, Moritz and Maune, Holger and Speck, Oliver and Wacker, Frank and Hensen, Bennet and Gutberlet, Marcel},
title = {Flexible and wireless metasurface coils for knee and elbow MRI},
journal = {European Radiology Experimental},
year = {2025},
doi = {10.1186/s41747-024-00549-8}
}
EUVIMED