EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of the in vitro performance of the double forwarder knot, compared to square and surgeon's knots using large gauge suture

Harriet K Barnes, Amelia S Munsterman iD, Alex M Gillen, Stephanie S Caston, Dane M Tatarniuk, Kevin Kersh, Tamara Swor, R Reid Hanson

Veterinary Surgery · 2024

DOI: 10.1111/vsu.14058 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Surgery, 2024. Verfasst von Harriet K Barnes und 7 weiteren Autor:innen. Beteiligte Einrichtung: Philip Leverhulme Equine Hopsital, University of Liverpool, Neston, UK. Hauptthemen laut MEDLINE: Polyglactin 910, Surgeons. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Iowa State University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The aim of the study was to evaluate the strength and size of the double forwarder (DF) knot in 2 and 3 USP polyglactin 910 when used to form a ligature and to compare the knot holding capacity (KHC), size and weight of the DF knot to surgeon's (SU) and square (SQ) knots with varying numbers of throws. Study design Laboratory study. Study population Knotted suture.

Methods

Knots were tied using 2 and 3 USP polyglactin 910 and tested on a universal testing machine under linear tension. Mode of failure and (KHC) were recorded. Knot volume and weight were determined by digital micrometer and balance. KHC, size, and weight between knot type, number of throws, and suture type and size were compared using ANOVA testing, with p < .05 as significant.

Results

In both suture types, DF knots had a higher KHC than SQ/SU knots ( p < .004), with the exception of SU knots with 6–8 throws in 3 USP polyglactin 910 ( p > .42). All DF knots failed by suture breakage at the knot, as did all SQ/SU knots with >6 throws. DF knots in 2 and 3 USP polyglactin 910 were larger and heavier than SQ and SU knots when the same number of throws was applied ( p < .003).

Conclusion

Self‐locking DF knots provided increased strength compared to SU/SQ in large gauge suture but only when fewer than six throws are applied to SU/SQ knots. Clinical relevance The new DF knot could be an alternative for a secure ligature.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Polyglactin 910SurgeonsAnimalsHumansSuture TechniquesTensile StrengthSuturesMaterials Testing

Substanzen

Polyglactin 910

Autor:innen und Institutionen

  • Philip Leverhulme Equine Hopsital, University of Liverpool, Neston, UK.
  • Veterinary Medical Center, Michigan State University, East Lansing, Michigan, USA.
  • Performance Equine Vets, Aiken, South Carolina, USA.
  • Highline Veterinary Orthopedics, Fairmont, Minnesota, USA.
  • Lloyd Large Animal Hospital, Iowa State University, Ames, Iowa, USA.
  • JT Vaughan Large Animal Teaching Hospital, Auburn University, Auburn, Alabama, USA.

ORCID-Profile: Amelia S Munsterman

Förderung

  • Iowa State University

Zitieren

APA

Barnes, H. K., Munsterman, A. S., Gillen, A. M., Caston, S. S., Tatarniuk, D. M., Kersh, K., Swor, T., & Hanson, R. R. (2024). Evaluation of the in vitro performance of the double forwarder knot, compared to square and surgeon's knots using large gauge suture. Veterinary Surgery. https://doi.org/10.1111/vsu.14058

Vancouver

Barnes HK, Munsterman AS, Gillen AM, Caston SS, Tatarniuk DM, Kersh K, et al. Evaluation of the in vitro performance of the double forwarder knot, compared to square and surgeon's knots using large gauge suture. Veterinary Surgery. 2024. doi:10.1111/vsu.14058

BibTeX
@article{Barnes2024,
  author = {Barnes, Harriet K and Munsterman, Amelia S and Gillen, Alex M and Caston, Stephanie S and Tatarniuk, Dane M and Kersh, Kevin and Swor, Tamara and Hanson, R Reid},
  title = {Evaluation of the in vitro performance of the double forwarder knot, compared to square and surgeon's knots using large gauge suture},
  journal = {Veterinary Surgery},
  year = {2024},
  doi = {10.1111/vsu.14058}
}
Kostenlos starten →