EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Hybrid Electrospun-Extruded Polydioxanone Suture for Tendon Tissue Regeneration

Roxanna E Abhari iD, Sarah J B Snelling, Edyta Augustynak, Simon Davis, Roman Fischer, Andrew J Carr, Pierre-Alexis Mouthuy

Tissue Engineering Part A · 2024

DOI: 10.1089/ten.tea.2023.0273 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tissue Engineering Part A, 2024. Verfasst von Roxanna E Abhari und 6 weiteren Autor:innen. Beteiligte Einrichtung: Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences, University of Oxford, Oxford, United Kingdom. Hauptthemen laut MEDLINE: Polydioxanone, Polyglactin 910. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Many surgical tendon repairs fail despite advances in surgical materials and techniques. Tendon repair failure can be partially attributed to the tendon's poor intrinsic healing capacity and the repurposing of sutures from other clinical applications. Electrospun materials show promise as a biological scaffold to support endogenous tendon repair, but their relatively low tensile strength has limited their clinical translation. It is hypothesized that combining electrospun fibers with a material with increased tensile strength may improve the suture's mechanical properties while retaining biophysical cues necessary to encourage cell-mediated repair. This article describes the production of a hybrid electrospun-extruded suture with a sheath of submicron electrospun fibers and a core of melt-extruded fibers. The porosity and tensile strength of this hybrid suture is compared with an electrospun-only braided suture and clinically used sutures Vicryl and polydioxanone (PDS). Bioactivity is assessed by measuring the adsorbed serum proteins on electrospun and melt-extruded filaments using mass spectrometry. Human hamstring tendon fibroblast attachment and proliferation were quantified and compared between the hybrid and control sutures. Combining an electrospun sheath with melt-extruded cores created a hybrid braid with increased tensile strength (70.1 ± 0.3N) compared with an electrospun only suture (12.9 ± 1 N, p < 0.0001). The hybrid suture had a similar force at break to clinical sutures, but lower stiffness and stress. The Young's modulus was 772.6 ± 32 MPa for the hybrid suture, 1693.0 ± 69 MPa for PDS, and 3838.0 ± 132 MPa for Vicryl, p < 0.0001. Hybrid sutures had lower overall porosity than electrospun-only sutures (40 ± 4% and 60 ± 7%, respectively, p = 0.0018) but had a significantly larger overall porosity and average pore diameter compared with surgical sutures. There were similar clusters of adsorbed proteins on electrospun and melt-extruded filaments, which were distinct from PDS. Tendon fibroblast attachment and cell proliferation on hybrid and electrospun sutures were significantly higher than on clinical sutures. This study demonstrated that a bioactive suture with increased tensile strength and lower stiffness could be produced by adding a core of 10 μm melt-extruded fibers to a sheath of electrospun fibers. In contrast to currently used sutures, the hybrid sutures promoted a bioactive response: serum proteins adsorbed, and fibroblasts attached, survived, grew along the sutures, and adopted appropriate morphologies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PolydioxanonePolyglactin 910HumansSuture TechniquesTendonsSuturesTensile StrengthBlood Proteins

Stichwörter der Autor:innen

biomaterialspolymeric scaffoldstissue engineering

Substanzen

PolydioxanonePolyglactin 910Blood Proteins

Autor:innen und Institutionen

  • Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences, University of Oxford, Oxford, United Kingdom.
  • Nuffield Department of Medicine, Target Discovery Institute, Centre for Medicines Discovery, University of Oxford, Oxford, United Kingdom.
  • Nuffield Department of Medicine, Chinese Academy for Medical Sciences Oxford Institute, University of Oxford, Oxford, United Kingdom.

ORCID-Profile: Roxanna E Abhari

Zitieren

APA

Abhari, R. E., Snelling, S. J. B., Augustynak, E., Davis, S., Fischer, R., Carr, A. J., & Mouthuy, P. A. (2024). A Hybrid Electrospun-Extruded Polydioxanone Suture for Tendon Tissue Regeneration. Tissue Engineering Part A. https://doi.org/10.1089/ten.tea.2023.0273

Vancouver

Abhari RE, Snelling SJB, Augustynak E, Davis S, Fischer R, Carr AJ, et al. A Hybrid Electrospun-Extruded Polydioxanone Suture for Tendon Tissue Regeneration. Tissue Engineering Part A. 2024. doi:10.1089/ten.tea.2023.0273

BibTeX
@article{Abhari2024,
  author = {Abhari, Roxanna E and Snelling, Sarah J B and Augustynak, Edyta and Davis, Simon and Fischer, Roman and Carr, Andrew J and Mouthuy, Pierre-Alexis},
  title = {A Hybrid Electrospun-Extruded Polydioxanone Suture for Tendon Tissue Regeneration},
  journal = {Tissue Engineering Part A},
  year = {2024},
  doi = {10.1089/ten.tea.2023.0273}
}
Kostenlos starten →