EUVIMEDEUVIMED entdecken
Open Access

Clinical Impact of Measurement Timing on Intraocular Pressure in Dogs

Seoyeong Lee iD, Sunjun Jung iD

Veterinary Ophthalmology · 2026

DOI: 10.1111/vop.70234 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Ophthalmology, 2026. Verfasst von Seoyeong Lee und 1 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Veterinary Ophthalmology, Department of Veterinary Medicine, College of Veterinary Medicine, Kyungpook National University, Daegu, Repu…. Hauptthemen laut MEDLINE: Intraocular Pressure, Tonometry, Ocular, Dog Diseases. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The objective of this study is to determine whether intraocular pressure (IOP) varies with the timing of measurement after patient presentation and whether such differences significantly affect clinical interpretation. Animal Studied A total of 88 eyes from 44 dogs presenting for their first ophthalmologic examination were included. All IOP measurements were performed by the same examiner at a single institution. Procedure(s) IOP was first measured immediately after history taking once the owner had left the examination room (IOP_0min). During the subsequent five minutes, Schirmer tear test‐1 and neuro‐ophthalmic examinations were performed, followed by a second IOP measurement (IOP_5min). IOP_0min, IOP_5min, and changes in IOP (ΔIOP) were analyzed according to sex, body weight, age, and visual status.

Results

The mean IOP_0min was 16.55 ± 4.63 mmHg, and the mean IOP_5min decreased to 13.06 ± 3.44 mmHg ( p < 0.001). Statistically significant IOP reduction was observed within all subgroups, including those divided according to sex, body weight, age, and visual status (all p < 0.001). Females and dogs weighing > 5 kg showed greater reductions in IOP compared to males and dogs weighing ≤ 5 kg ( p < 0.05). No significant differences were observed based on age or visual status.

Conclusions

IOP decreases statistically significantly within minutes of patient presentation, and this reduction was observed across all subgroups. These findings highlight that the timing of IOP measurement should be standardized to ensure an accurate and reproducible assessment, ultimately allowing for precise evaluation of the patient's ocular condition.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intraocular PressureTonometry, OcularDog DiseasesAnimalsDogsMaleFemaleTime Factors

Stichwörter der Autor:innen

IOP changecanineclinical monitoringhospitalophthalmic examinationrebound tonometry

Autor:innen und Institutionen

  • Laboratory of Veterinary Ophthalmology, Department of Veterinary Medicine, College of Veterinary Medicine, Kyungpook National University, Daegu, Republic of Korea.

ORCID-Profile: Seoyeong Lee, Sunjun Jung

Zitieren

APA

Lee, S., & Jung, S. (2026). Clinical Impact of Measurement Timing on Intraocular Pressure in Dogs. Veterinary Ophthalmology. https://doi.org/10.1111/vop.70234

Vancouver

Lee S, Jung S. Clinical Impact of Measurement Timing on Intraocular Pressure in Dogs. Veterinary Ophthalmology. 2026. doi:10.1111/vop.70234

BibTeX
@article{Lee2026,
  author = {Lee, Seoyeong and Jung, Sunjun},
  title = {Clinical Impact of Measurement Timing on Intraocular Pressure in Dogs},
  journal = {Veterinary Ophthalmology},
  year = {2026},
  doi = {10.1111/vop.70234}
}
Kostenlos starten →