The White Coat Effect Influences Intraocular Pressure Measurements in Dogs: Comparing Tonometry Values Obtained in the Clinic Versus Home
Veterinary Ophthalmology · 2026
DOI: 10.1111/vop.70113 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Veterinary Ophthalmology, 2026. Verfasst von Ruth Pentlarge Barrow und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgical Sciences, School of Veterinary Medicine, Madison, Wisconsin (WI), USA. Hauptthemen laut MEDLINE: Intraocular Pressure, Tonometry, Ocular. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NEI NIH HHS, NIH HHS, Research to Prevent Blindness.
Abstract (Originalsprache)
Objective
To determine the effect of clinic versus home environments on intraocular pressure (IOP) measurements in normotensive dogs. Animals Forty client‐owned normotensive dogs.
Methods
In a prospective crossover study, 40 normotensive dogs were included following a complete ophthalmic examination. IOPs were measured in both eyes for each dog using a TonoVet rebound tonometer by a single observer. IOPs were measured in the clinic after the ophthalmic examination, and in the home upon initial entry by the observer (t = 0) and 10 min later (t = 10). Paired t‐tests were performed to compare IOP in the clinic versus home and adjusted p < 0.05 followed by the Holm‐Šídák correction were considered significant.
Results
Mean IOP in the clinic (15.7 mmHg ±2.7) was significantly higher than mean IOP in the home at both t = 0 (14.2 mmHg ±2.2; p < 0.0001) and t = 10 (12.9 mmHg ±1.9; p < 0.0001). Mean IOP in the home at t = 0 (14.2 mmHg ±2.2) was significantly higher than mean IOP in the home at t = 10 (12.9 mmHg ±1.9; p = 0.0001). There was no significant effect of testing site sequence on IOP.
Conclusion
IOPs measured by tonometry in the clinic are elevated relative to IOPs obtained in the home, by up to 10 mmHg in one eye in this study. Changes in IOP may be rapid, as seen with the significant reduction in IOP over 10 min of acclimation in the home setting. Veterinarians should consider these findings when interpreting IOP values, especially in dogs that are stressed by the clinic environment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgical Sciences, School of Veterinary Medicine, Madison, Wisconsin (WI), USA.
- McPherson Eye Research Institute, Madison, Wisconsin (WI), USA.
- Department of Ophthalmology and Visual Sciences, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA.
ORCID-Profile: Ruth Pentlarge Barrow, Kazuya Oikawa, Gillian J McLellan
Förderung
- NEI NIH HHS
- NIH HHS
- Research to Prevent Blindness
- National Institutes of Health
Zitieren
APA
Barrow, R. P., Strong, T., Oikawa, K., McLellan, G. J., & Bentley, E. (2026). The White Coat Effect Influences Intraocular Pressure Measurements in Dogs: Comparing Tonometry Values Obtained in the Clinic Versus Home. Veterinary Ophthalmology. https://doi.org/10.1111/vop.70113
Vancouver
Barrow RP, Strong T, Oikawa K, McLellan GJ, Bentley E. The White Coat Effect Influences Intraocular Pressure Measurements in Dogs: Comparing Tonometry Values Obtained in the Clinic Versus Home. Veterinary Ophthalmology. 2026. doi:10.1111/vop.70113
BibTeX
@article{Barrow2026,
author = {Barrow, Ruth Pentlarge and Strong, Travis and Oikawa, Kazuya and McLellan, Gillian J and Bentley, Ellison},
title = {The White Coat Effect Influences Intraocular Pressure Measurements in Dogs: Comparing Tonometry Values Obtained in the Clinic Versus Home},
journal = {Veterinary Ophthalmology},
year = {2026},
doi = {10.1111/vop.70113}
}
EUVIMED