EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of TonoLab , TonoVet Plus, and Tono‐Pen AVIA Vet Tonometers for Measuring Intraocular Pressure in Rats

Tarcísio Guerra Guimarães iD, Antônio Felipe P F Wouk iD, Karla Menezes Cardoso iD, Francisco Caramelo iD, Luís Carvalho iD, João Monteiro iD, Carlos Miguel Marto iD, António Francisco Ambrósio iD, Nuno Alexandre iD, Maria Filomena Botelho iD, Mafalda Laranjo iD

Veterinary Ophthalmology · 2026

DOI: 10.1111/vop.70139 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Veterinary Ophthalmology, 2026. Verfasst von Tarcísio Guerra Guimarães und 10 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, University of Coimbra, Coimbra Institute for Clinical and Biomedical Research (iCBR), area of Environment Genetics and Oncobiolo…. Hauptthemen laut MEDLINE: Intraocular Pressure, Tonometry, Ocular. Die Arbeit nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e a Tecnologia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To assess the agreement between intraocular pressure (IOP) measurements in rats using different animal‐adapted tonometers and to evaluate the relation among the devices.

Methods

IOP was measured using the TonoLab tonometer, followed by the TonoVet Plus and finally, the Tono‐Pen AVIA Vet. A total of 24 eyes were studied from 12 healthy Wistar rats anesthetized with sevoflurane. Agreement analysis was performed between the TonoLab tonometer and the TonoVet Plus, and the TonoLab and Tono‐Pen AVIA Vet using the intraclass correlation coefficient (ICC). For the tested pairs, Bland–Altman graphs were also performed. The relation of TonoVet Plus and Tono‐Pen AVIA Vet tonometers to TonoLab was also evaluated using a simple linear regression.

Results

The agreement between the TonoLab tonometers and the TonoVet Plus was weak (ICC = 0.173, 95% CI [−0.129; 0.489], p = 0.130) and not statistically significant. The agreement between the TonoLab and the Tono‐Pen AVIA Vet tonometers was negligible (ICC = 0.011, 95% CI [−0.117; 0.218], p = 0.448). Linear regression analysis between the TonoLab and the TonoVet Plus ( p = 0.256), as well as between the TonoLab and the Tono‐Pen AVIA Vet ( p = 0.897), was not statistically significant.

Conclusions

The measurements revealed a consistent pattern in which the Tono‐Pen AVIA Vet showed the highest mean IOP values, followed by the TonoVet Plus and the TonoLab. Knowing the normal values of indirect IOP in rats for each of these tonometers, as well as the differences between them, is fundamental for the proper interpretation of the measurements obtained and for allowing reliable comparisons between the devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intraocular PressureTonometry, OcularAnimalsRatsRats, WistarMaleReproducibility of Results

Stichwörter der Autor:innen

Wistar ratapplanation tonometryrebound tonometrytonometer

Autor:innen und Institutionen

  • Faculty of Medicine, University of Coimbra, Coimbra Institute for Clinical and Biomedical Research (iCBR), area of Environment Genetics and Oncobiology (CIMAGO) and Institute of Biophysics, Faculty of Medicine, Coimbra,…
  • University of Évora, Institute for Advanced Studies and Research (IIFA) and Mediterranean Institute for Agriculture, Environment and Development (MED), Évora, Portugal.
  • Center for Innovative Biomedicine and Biotechnology (CiBB), University of Coimbra, Coimbra, Portugal.
  • Division of Veterinary Ophthalmology, Department of Veterinary Medicine, Federal University of Paraná (UFPR) and MeBi Veterinary Hospital, Curitiba, Paraná, Brazil.
  • Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal.
  • Vet World Veterinary Clinic, Figueira da Foz, Portugal.

ORCID-Profile: Tarcísio Guerra Guimarães, Antônio Felipe P F Wouk, Karla Menezes Cardoso, Francisco Caramelo, Luís Carvalho, João Monteiro, Carlos Miguel Marto, António Francisco Ambrósio, Nuno Alexandre, Maria Filomena Botelho, Mafalda Laranjo

Förderung

  • Fundação para a Ciência e a Tecnologia

Zitieren

APA

Guimarães, T. G., Wouk, A. F. P. F., Cardoso, K. M., Caramelo, F., Carvalho, L., Monteiro, J., Marto, C. M., Ambrósio, A. F., Alexandre, N., Botelho, M. F., & Laranjo, M. (2026). Comparison of TonoLab , TonoVet Plus, and Tono‐Pen AVIA Vet Tonometers for Measuring Intraocular Pressure in Rats. Veterinary Ophthalmology. https://doi.org/10.1111/vop.70139

Vancouver

Guimarães TG, Wouk AFPF, Cardoso KM, Caramelo F, Carvalho L, Monteiro J, et al. Comparison of TonoLab , TonoVet Plus, and Tono‐Pen AVIA Vet Tonometers for Measuring Intraocular Pressure in Rats. Veterinary Ophthalmology. 2026. doi:10.1111/vop.70139

BibTeX
@article{Guimares2026,
  author = {Guimarães, Tarcísio Guerra and Wouk, Antônio Felipe P F and Cardoso, Karla Menezes and Caramelo, Francisco and Carvalho, Luís and Monteiro, João and Marto, Carlos Miguel and Ambrósio, António Francisco and Alexandre, Nuno and Botelho, Maria Filomena and Laranjo, Mafalda},
  title = {Comparison of TonoLab , TonoVet Plus, and Tono‐Pen AVIA Vet Tonometers for Measuring Intraocular Pressure in Rats},
  journal = {Veterinary Ophthalmology},
  year = {2026},
  doi = {10.1111/vop.70139}
}
Kostenlos starten →