EUVIMEDEUVIMED entdecken
Open Access

Evaluation of Point‐of‐Care Coagulation Measurement Systems for Activated Clotting Time and Partial Thromboplastin Time in Heparinized and Non‐Heparinized Equine Blood

Kallie J Hobbs, Yu Ueda, Yang Qu, Bethanie L Cooper, M Katie Sheats, Megan J Burke

Journal of Veterinary Emergency and Critical Care · 2026-05 · 36 (3) · 330-335

DOI: 10.1111/vec.70127 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Veterinary Emergency and Critical Care, online erschienen am 09.06.2026. Verfasst von Kallie J Hobbs und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences, Texas A&M University, College Station, Texas, USA. Hauptthemen laut MEDLINE: Point-of-Care Systems. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: North Carolina State University Intramural Fund, Thoroughbred Education and Research Foundation Young Investigator Grant.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To compare the performance of one point‐of‐care activated clotting time (ACT) machine (Vet‐Tube), one point‐of‐care activated partial thromboplastin time (aPTT) machine (Coagulation DX), and one bench‐top ACT machine (Medtronic ACT II plus) with previously published measurements from stationary devices in whole blood from healthy horses.

Design

Prospective, observational study Setting University veterinary teaching hospital, from August 2023 to September 2023. Animals Thirty healthy university‐owned horses.

Methods

ACT and aPTT were measured via point‐of‐care analyzers (ACT POC, aPTT POC) and by conventional stationary analyzers (ACT Stationary, aPTT Stationary) in non‐heparinized and heparinized blood collected from healthy horses. Samples were analyzed within 30 min of collection.

Results

Moderate correlation ( r = 0.5), acceptable bias, and a low intraassay coefficient of variation (5%) were seen for the aPTT POC device, with the aPTT stationary device being within previously published ranges. The aPTT stationary chemistry analyzer and aPTT POC showed a significant difference for non‐heparinized samples ( n = 30, p = 0.0002) but had no significant difference for heparinized samples ( n = 15, p = 0.03). Clinical Relevance The results of this study provide proof of concept for the use of low‐cost POC monitoring of ACT in equine patients with coagulopathy or undergoing heparin therapy. Rigorous evaluation in patients with clinical disease is still necessary.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Point-of-Care SystemsAnimalsHorsesPartial Thromboplastin TimeHeparinProspective StudiesAnticoagulantsBlood Coagulation TestsFemaleBlood CoagulationWhole Blood Coagulation TimeMale

Stichwörter der Autor:innen

extracorporealhorsesepsis

Substanzen

HeparinAnticoagulants

Autor:innen und Institutionen

  • Department of Clinical Sciences, Texas A&M University, College Station, Texas, USA.
  • Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina, USA.

Förderung

  • North Carolina State University Intramural Fund
  • Thoroughbred Education and Research Foundation Young Investigator Grant

Zitieren

APA

Hobbs, K. J., Ueda, Y., Qu, Y., Cooper, B. L., Sheats, M. K., & Burke, M. J. (2026). Evaluation of Point‐of‐Care Coagulation Measurement Systems for Activated Clotting Time and Partial Thromboplastin Time in Heparinized and Non‐Heparinized Equine Blood. Journal of Veterinary Emergency and Critical Care, 36(3), 330-335. https://doi.org/10.1111/vec.70127

Vancouver

Hobbs KJ, Ueda Y, Qu Y, Cooper BL, Sheats MK, Burke MJ. Evaluation of Point‐of‐Care Coagulation Measurement Systems for Activated Clotting Time and Partial Thromboplastin Time in Heparinized and Non‐Heparinized Equine Blood. Journal of Veterinary Emergency and Critical Care. 2026;36(3):330-335. doi:10.1111/vec.70127

BibTeX
@article{Hobbs2026,
  author = {Hobbs, Kallie J and Ueda, Yu and Qu, Yang and Cooper, Bethanie L and Sheats, M Katie and Burke, Megan J},
  title = {Evaluation of Point‐of‐Care Coagulation Measurement Systems for Activated Clotting Time and Partial Thromboplastin Time in Heparinized and Non‐Heparinized Equine Blood},
  journal = {Journal of Veterinary Emergency and Critical Care},
  year = {2026},
  volume = {36},
  number = {3},
  pages = {330--335},
  doi = {10.1111/vec.70127}
}
Kostenlos starten →