EUVIMEDEUVIMED entdecken
Kohortenstudie

Anticoagulation Monitoring Strategies During Extracorporeal Membrane Oxygenation (ECMO) Therapy – Differences Between Simultaneously Obtained Coagulation Tests: A Retrospective Single-Center Cohort Study

Alexander C Reisinger iD, Nikolaus Schneider, Marco Koellinger, Stefan Hatzl, Gerald Hackl, Reinhard Raggam, Dirk von Lewinski, Florian Posch, Philipp Eller iD

Journal of Intensive Care Medicine · 2025-06 · 40 (6) · 651-659

DOI: 10.1177/08850666241313357 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Journal of Intensive Care Medicine, online erschienen am 06.02.2025. Verfasst von Alexander C Reisinger und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Intensive Care Unit, Medical University of Graz, Graz, Austria. Hauptthemen laut MEDLINE: Extracorporeal Membrane Oxygenation, Anticoagulants, Drug Monitoring. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

During extracorporeal membrane oxygenation (ECMO) systemic anticoagulation with unfractionated heparin (UFH) is standard-of-care. However, there is uncertainty regarding optimal anticoagulation monitoring strategies.

Methods

We retrospectively investigated venovenous and venoarterial ECMO patients at the medical ICUs at the Medical University of Graz, Austria. We analyzed the correlation and concordance of R-time in thromboelastography (TEG), activated partial thromboplastin time (aPTT), and anti-Xa activity. The proportion within target range, the association of coagulation parameters above or below target range (aPTT 54–72 s; equals 1.5–2× upper limit of normal (ULN), anti-Xa activity 0.2–0.5 U/mL, and R-time in assays without heparinase 675–900 s; equals 1.5–2× ULN) with mortality, bleeding events and thrombotic complications were investigated.

Results

We analyzed 671 clusters of simultaneously performed coagulation tests in 85 ECMO cases that fulfilled inclusion criteria. Median age of patients was 57 years and 32% were female. There were poor correlations between the three coagulation tests and the proportion of discordance was 46%. Within the target range were 21% of R-time, 15% of aPTT, and 44% of anti-Xa activity measurements. Singular and multiple bleeding events occurred in 25 and 32 patients, respectively. The most common bleeding locations were catheter and cannula insertion sites followed by pulmonary hemorrhage. In VA-ECMO, anti-Xa activity was associated (OR 1.03 [1.01–1.06], p = 0.005) and correlated with bleeding events (spearman rho 0.49, p = 0.002; point biserial 0.49, p = 0.001). aPTT level below target range was associated with reduced mortality (OR 0.98 [0.97–0.99], p = 0.024). Thrombotic events occurred in six patients with no association of coagulation tests.

Conclusion

There was a high rate of discordance and poor correlation between aPTT, anti-Xa activity and R-time in TEG in ECMO patients. We found high rates of bleeding events and in VA-ECMO an association with elevated anti-Xa activity levels.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Extracorporeal Membrane OxygenationAnticoagulantsDrug MonitoringHumansRetrospective StudiesFemaleMaleMiddle AgedBlood Coagulation TestsPartial Thromboplastin TimeHeparinThrombelastographyAgedAustriaAdultIntensive Care Units

Stichwörter der Autor:innen

ECMOTEGanti-Xa activityextracorporealheparinviscoelastic

Substanzen

AnticoagulantsHeparin

Autor:innen und Institutionen

  • Department of Internal Medicine, Intensive Care Unit, Medical University of Graz, Graz, Austria.
  • Department of Internal Medicine, Division of Angiology, Medical University of Graz, Graz, Austria.
  • Department of Internal Medicine, Division of Cardiology, Medical University of Graz, Graz, Austria.
  • Department of Internal Medicine, Division of Hematology, Medical University of Graz, Graz, Austria.

ORCID-Profile: Alexander C Reisinger, Philipp Eller

Zitieren

APA

Reisinger, A. C., Schneider, N., Koellinger, M., Hatzl, S., Hackl, G., Raggam, R., von Lewinski, D., Posch, F., & Eller, P. (2025). Anticoagulation Monitoring Strategies During Extracorporeal Membrane Oxygenation (ECMO) Therapy – Differences Between Simultaneously Obtained Coagulation Tests: A Retrospective Single-Center Cohort Study. Journal of Intensive Care Medicine, 40(6), 651-659. https://doi.org/10.1177/08850666241313357

Vancouver

Reisinger AC, Schneider N, Koellinger M, Hatzl S, Hackl G, Raggam R, et al. Anticoagulation Monitoring Strategies During Extracorporeal Membrane Oxygenation (ECMO) Therapy – Differences Between Simultaneously Obtained Coagulation Tests: A Retrospective Single-Center Cohort Study. Journal of Intensive Care Medicine. 2025;40(6):651-659. doi:10.1177/08850666241313357

BibTeX
@article{Reisinger2025,
  author = {Reisinger, Alexander C and Schneider, Nikolaus and Koellinger, Marco and Hatzl, Stefan and Hackl, Gerald and Raggam, Reinhard and von Lewinski, Dirk and Posch, Florian and Eller, Philipp},
  title = {Anticoagulation Monitoring Strategies During Extracorporeal Membrane Oxygenation (ECMO) Therapy – Differences Between Simultaneously Obtained Coagulation Tests: A Retrospective Single-Center Cohort Study},
  journal = {Journal of Intensive Care Medicine},
  year = {2025},
  volume = {40},
  number = {6},
  pages = {651--659},
  doi = {10.1177/08850666241313357}
}
Kostenlos starten →