Assessment of Physiological Signals from Photoplethysmography Sensors Compared to an Electrocardiogram Sensor: A Validation Study in Daily Life
Sensors · 24.10.2024 · 24 (21) · 6826
DOI: 10.3390/s24216826 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 24.10.2024. Verfasst von Rana Zia Ur Rehman und 15 weiteren Autor:innen. Beteiligte Einrichtung: Janssen Research & Development, Buckinghamshire HP12 4EG, UK. Hauptthemen laut MEDLINE: Photoplethysmography, Heart Rate, Electrocardiography, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 39-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Wearables with photoplethysmography (PPG) sensors are being increasingly used in clinical research as a non-invasive, inexpensive method for remote monitoring of physiological health. Ensuring the accuracy and reliability of PPG-derived measurements is critical, as inaccuracies can impact research findings and clinical decisions. This paper systematically compares heart rate (HR) and heart rate variability (HRV) measures from PPG against an electrocardiogram (ECG) monitor in free-living settings. Two devices with PPG and one device with an ECG sensor were worn by 25 healthy volunteers for 10 days. PPG-derived HR and HRV showed reasonable accuracy and reliability, particularly during sleep, with mean absolute error < 1 beat for HR and 6–15 ms for HRV. The relative error of HRV estimated from PPG varied with activity type and was higher than during the resting state by 14–51%. The accuracy of HR/HRV was impacted by the proportion of usable data, body posture, and epoch length. The multi-scale peak and trough detection algorithm demonstrated superior performance in detecting beats from PPG signals, with an F1 score of 89% during sleep. The study demonstrates the trade-offs of utilizing PPG measurements for remote monitoring in daily life and identifies optimal use conditions by recommending enhancements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Janssen Research & Development, Buckinghamshire HP12 4EG, UK.
- Janssen Research & Development, Cambridge, MA 02142, USA.
- Janssen Research & Development, 2340 Beerse, Belgium.
- Janssen Research & Development, LLC, San Diego, CA 92121, USA.
- Janssen Research & Development, Raritan, NJ 08869, USA.
- Janssen Research & Development, Spring House, PA 19477, USA.
ORCID-Profile: Rana Zia Ur Rehman, Meenakshi Chatterjee, Nikolay V Manyakov, Sophie Smets, Molly V Lucas, Tommaso Mansi
Zitieren
APA
Rehman, R. Z. U., Chatterjee, M., Manyakov, N. V., Daans, M., Jackson, A., O'Brisky, A., Telesky, T., Smets, S., Berghmans, P. J., Yang, D., Reynoso, E., Lucas, M. V., Huo, Y., Thirugnanam, V. T., Mansi, T., & Morris, M. (2024). Assessment of Physiological Signals from Photoplethysmography Sensors Compared to an Electrocardiogram Sensor: A Validation Study in Daily Life. Sensors, 24(21), 6826. https://doi.org/10.3390/s24216826
Vancouver
Rehman RZU, Chatterjee M, Manyakov NV, Daans M, Jackson A, O'Brisky A, et al. Assessment of Physiological Signals from Photoplethysmography Sensors Compared to an Electrocardiogram Sensor: A Validation Study in Daily Life. Sensors. 2024;24(21):6826. doi:10.3390/s24216826
BibTeX
@article{Rehman2024,
author = {Rehman, Rana Zia Ur and Chatterjee, Meenakshi and Manyakov, Nikolay V and Daans, Melina and Jackson, Amanda and O'Brisky, Andrea and Telesky, Tacie and Smets, Sophie and Berghmans, Pieter-Jan and Yang, Dongyan and Reynoso, Elena and Lucas, Molly V and Huo, Yanran and Thirugnanam, Vasanth T and Mansi, Tommaso and Morris, Mark},
title = {Assessment of Physiological Signals from Photoplethysmography Sensors Compared to an Electrocardiogram Sensor: A Validation Study in Daily Life},
journal = {Sensors},
year = {2024},
volume = {24},
number = {21},
pages = {6826},
doi = {10.3390/s24216826}
}
EUVIMED