Impact of Anatomical Placement on the Accuracy of Wearable Heart Rate Monitors During Rest and Various Exercise Intensities

Masoud Moghaddam iD, James P Collins, Caroline E Gardner, Michael C Rabel

Sensors · 2025

DOI: 10.3390/s26010176 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Masoud Moghaddam und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy, School of Pharmacy and Health Professions, University of Maryland Eastern Shore, Hazel Hall, Suite 2082, Princess Ann…. Hauptthemen laut MEDLINE: Heart Rate, Wearable Electronic Devices, Exercise, Rest. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study evaluated the accuracy of arm-based photoplethysmography (PPG) wearable heart rate (HR) monitors in comparison to a validated chest strap reference across various activity levels.

Methods

Twenty-eight healthy adults (14 males, 14 females; aged 23.8 ± 1.1 years) wore six HR monitors: Polar H10 chest strap, Polar Verity Sense on the forearm, Garmin Forerunner on the wrist, and three identical Whoop 4.0 devices placed on the left wrist, forearm, and upper arm. Participants completed rest, warm-up, high-intensity burpees, and graded treadmill exercise. HR data were analyzed using mean absolute percentage error (MAPE), Bland–Altman analysis, concordance correlation coefficient (CCC), and Deming regression.

Results

Accuracy was highest at rest and gradually decreased as movement intensity increased. During rest, all devices showed minimal bias and high agreement (CCC > 0.99), with Verity Sense recording the lowest MAPE. In warm-up, Whoop-upper arm and Verity Sense outperformed wrist and Garmin positions, while the Whoop-forearm showed proportional and systematic bias. Burpees resulted in the lowest accuracy across devices (CCC < 0.50), but Whoop-upper arm performed better than other placements. During the Modified Bruce protocol, Verity Sense and Whoop-upper arm had the strongest agreement with the chest strap. Placement of identical Whoop units affected accuracy, with the upper arm outperforming forearm and wrist positions.

Conclusions

PPG wearables provided accurate HR monitoring at rest, during warm-up, and during steady-state graded exercise, particularly when positioned proximally (forearm or upper arm). Accuracy declined during short, high-intensity, full-body activities due to motion artifacts. Both the forearm-mounted Verity Sense and the upper-arm Whoop demonstrated the closest agreement with the chest-strap reference. The intra-device comparison of identical Whoop units confirmed that anatomical placement alone significantly affects accuracy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart RateWearable Electronic DevicesExerciseRestHumansFemaleMaleAdultYoung AdultPhotoplethysmographyMonitoring, PhysiologicArmForearm

Stichwörter der Autor:innen

accuracyheart rate monitoringphotoplethysmographysensor placementvalidation studywearable technology

Autor:innen und Institutionen

  • Department of Physical Therapy, School of Pharmacy and Health Professions, University of Maryland Eastern Shore, Hazel Hall, Suite 2082, Princess Anne, MD 21853, USA.

ORCID-Profile: Masoud Moghaddam

Zitieren

APA

Moghaddam, M., Collins, J. P., Gardner, C. E., & Rabel, M. C. (2025). Impact of Anatomical Placement on the Accuracy of Wearable Heart Rate Monitors During Rest and Various Exercise Intensities. Sensors. https://doi.org/10.3390/s26010176

Vancouver

Moghaddam M, Collins JP, Gardner CE, Rabel MC. Impact of Anatomical Placement on the Accuracy of Wearable Heart Rate Monitors During Rest and Various Exercise Intensities. Sensors. 2025. doi:10.3390/s26010176

BibTeX
@article{Moghaddam2025,
  author = {Moghaddam, Masoud and Collins, James P and Gardner, Caroline E and Rabel, Michael C},
  title = {Impact of Anatomical Placement on the Accuracy of Wearable Heart Rate Monitors During Rest and Various Exercise Intensities},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s26010176}
}