Ultraviolet radiation thin film dosimetry: A review of properties and applications
Photochemistry and Photobiology · 2025
DOI: 10.1111/php.14022 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Photochemistry and Photobiology, 2025. Verfasst von Alfio V Parisi und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Mathematics, Physics and Computing, University of Southern Queensland, Toowoomba, Queensland, Australia. Hauptthemen laut MEDLINE: Ultraviolet Rays, Film Dosimetry. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 156 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Spectroradiometry, radiometry, and dosimetry are employed for the measurement of ultraviolet radiation (UVR) irradiance and non‐ionizing exposure. Different types of UVR dosimeter have been developed for measuring personal and environmental UVR exposures since film dosimetry was pioneered in the 1970s. An important type of dosimeter is the thin film variant, which contains materials that undergo changes in optical absorbance when exposed to UVR. These changes can be measured at a specific wavelength using a spectrophotometer. Thin film dosimeters allow UVR exposure measurements on humans at various body sites during daily activities, as well as on plants, animals, and any sites of interest when utilized in a field environment. This review examines the properties and applications of five types of thin film UVR dosimeter that have different dynamic exposure limits and spectral responses. Polysulphone, with a spectral response approximating the human erythema action spectrum, was one of the first materials employed in thin film form for the measurement of UVR exposures up to 1 day, and up to 6 days with an extended dynamic range filter. Polyphenylene oxide has been characterized and employed for personal UVR exposure measurements up to approximately four summer days and has also been used for long‐term underwater UVR exposures. Phenothiazine and 8‐methoxypsoralen have been reported as suitable for the measurement of longer wavelength UVA exposures. Finally, polyvinyl chloride with an extended dynamic exposure range of over 3 weeks has been shown to have predominantly a spectral response in the UVB and extending up to 340 nm.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Mathematics, Physics and Computing, University of Southern Queensland, Toowoomba, Queensland, Australia.
- UQ College, University of Queensland, Brisbane, Queensland, Australia.
- UniSQ College, University of Southern Queensland, Toowoomba, Queensland, Australia.
- Office of Research, University of Southern Queensland, Toowoomba, Queensland, Australia.
ORCID-Profile: Damien P Igoe
Zitieren
APA
Parisi, A. V., Downs, N. J., Schouten, P., Igoe, D. P., Turner, J., Amar, A., Wainwright, L., Dawes, A., Butler, H., & Dekeyser, S. (2025). Ultraviolet radiation thin film dosimetry: A review of properties and applications. Photochemistry and Photobiology. https://doi.org/10.1111/php.14022
Vancouver
Parisi AV, Downs NJ, Schouten P, Igoe DP, Turner J, Amar A, et al. Ultraviolet radiation thin film dosimetry: A review of properties and applications. Photochemistry and Photobiology. 2025. doi:10.1111/php.14022
BibTeX
@article{Parisi2025,
author = {Parisi, Alfio V and Downs, Nathan J and Schouten, Peter and Igoe, Damien P and Turner, Joanna and Amar, Abdurazaq and Wainwright, Lisa and Dawes, Adrian and Butler, Harry and Dekeyser, Stijn},
title = {Ultraviolet radiation thin film dosimetry: A review of properties and applications},
journal = {Photochemistry and Photobiology},
year = {2025},
doi = {10.1111/php.14022}
}
EUVIMED