EUVIMEDEUVIMED entdecken
Crossref

Pulsed Field Ablation Integrated With 3D Mapping System for Pulmonary Vein Isolation in a Swine Model

Zheyi Gong, Yiqi Lu, Caijie Shen, Jiedong Zhou, Xiaoyue Tang, Tuo Zhou, Yuxin Hu, Yijun Sun, Songtao Hu, Mingjun Feng, Si Chen, Lipu Yu und 5 weitere

Pacing and Clinical Electrophysiology · 2026-11 · 49 (11) · 1835-1842

DOI: 10.1111/pace.70298 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 26.05.2026. Verfasst von Zheyi Gong und 16 weiteren Autor:innen. Beteiligte Einrichtung: Health Science Center, Ningbo University, Ningbo, China. Hauptthemen laut MEDLINE: Pulmonary Veins, Imaging, Three-Dimensional, Atrial Fibrillation, Catheter Ablation. Die Arbeit nennt 14 Literaturangaben. Gefördert von: Zhejiang Provincial Health Commission Science and Technology Program, Ningbo Key Research and Development Program of the Science and Technology Innovation Yongjiang Project, Zhejiang Province Leading Project for Leading Geese plan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pulsed field ablation (PFA) is a breakthrough therapeutic modality for atrial fibrillation that employs nonthermal irreversible electroporation to selectively ablate cardiomyocytes. This preclinical study evaluated the safety and efficacy of a novel PFA system for pulmonary vein isolation (PVI).

Objectives

This study aimed to assess the safety and efficacy of a preclinical used PFA system in achieving acute and durable PVI.

Methods

The PFA system—comprising two flexible circular catheters, a three‐dimensional mapping system (3DMS), and a pulsed field generator—was utilized for PVI. Bipolar, biphasic waveforms were delivered in six swine using a 7‐electrode circular catheter at the right superior pulmonary vein (RSPV) and a 14‐electrode catheter at the common inferior pulmonary vein (CIPV). All animals underwent repeat electrophysiological mapping immediately post‐procedure and at 3‐month follow‐up to assess lesion durability and procedural safety, followed by gross necropsy and histology.

Results

All targeted pulmonary veins were successfully isolated. A total of 22.7 ± 5.3 applications were delivered per animal, comprising 11.0 ± 1.9 applications using the 7‐electrode catheter and 11.7 ± 4.7 applications using the 14‐electrode catheter. Acute and durable PVI at 3‐month follow‐up was achieved in all swine. Histopathology assessment revealed 100% of transmural fibrotic lesions with a mean depth of 2.7 ± 0.6 mm at RSPV and 3.3 ± 1.4 mm at CIPV ( p = 0.372) with no evidence of inflammation, or thrombus formation. No ventricular arrhythmias occurred during PFA delivery, and no periprocedural adverse events were observed. Furthermore, no collateral damage—including esophageal injury or phrenic nerve paralysis—was detected at the 3‐month evaluation.

Conclusions

The 3DMS integrated PFA system demonstrated excellent acute and chronic efficacy in achieving PVI, with durable lesion formation and a favorable safety profile free from collateral tissue injury.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary VeinsImaging, Three-DimensionalAtrial FibrillationCatheter AblationSurgery, Computer-AssistedBody Surface Potential MappingAnimalsSwineIrreversible Electroporation TherapyDisease Models, AnimalEquipment DesignSystems Integration

Stichwörter der Autor:innen

atrial fibrillationpulmonary vein isolationpulsed field ablationthree‐dimensional mapping system

Autor:innen und Institutionen

  • Health Science Center, Ningbo University, Ningbo, China.
  • Cardiac Arrhythmia Center, The First Affiliated Hospital of Ningbo University, Ningbo, China.
  • Department of Research and Development, APT Medical Inc., Shanghai, China.
  • Department of Cardiology, University Center of Cardiovascular Science, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Division of Cardiology, The University of Arizona College of Medicine-Phoenix, Banner University Medical Center Phoenix, Phoenix, USA.

Förderung

  • Zhejiang Provincial Health Commission Science and Technology Program
  • Ningbo Key Research and Development Program of the Science and Technology Innovation Yongjiang Project
  • Zhejiang Province Leading Project for Leading Geese plan

Zitieren

APA

Gong, Z., Lu, Y., Shen, C., Zhou, J., Tang, X., Zhou, T., Hu, Y., Sun, Y., Hu, S., Feng, M., Chen, S., Yu, L., Zhuo, W., Zhang, J., Ouyang, F., Bai, R., & Chu, H. (2026). Pulsed Field Ablation Integrated With 3D Mapping System for Pulmonary Vein Isolation in a Swine Model. Pacing and Clinical Electrophysiology, 49(11), 1835-1842. https://doi.org/10.1111/pace.70298

Vancouver

Gong Z, Lu Y, Shen C, Zhou J, Tang X, Zhou T, et al. Pulsed Field Ablation Integrated With 3D Mapping System for Pulmonary Vein Isolation in a Swine Model. Pacing and Clinical Electrophysiology. 2026;49(11):1835-1842. doi:10.1111/pace.70298

BibTeX
@article{Gong2026,
  author = {Gong, Zheyi and Lu, Yiqi and Shen, Caijie and Zhou, Jiedong and Tang, Xiaoyue and Zhou, Tuo and Hu, Yuxin and Sun, Yijun and Hu, Songtao and Feng, Mingjun and Chen, Si and Yu, Lipu and Zhuo, Weidong and Zhang, Jie and Ouyang, Feifan and Bai, Rong and Chu, Huimin},
  title = {Pulsed Field Ablation Integrated With 3D Mapping System for Pulmonary Vein Isolation in a Swine Model},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  volume = {49},
  number = {11},
  pages = {1835--1842},
  doi = {10.1111/pace.70298}
}
Kostenlos starten →