EUVIMEDEUVIMED entdecken
Crossref

Balloon‐Shaped Pulsed Field Ablation for Pulmonary Vein Isolation and Atrial Lesions

Song Zuo iD, Caihua Sang iD, Jue Wang, Xiangyi Kong, Jingrui Zhang, Mingyang Gao, Wenli Dai, Junmeng Zhang, Xueyuan Guo, Xiaoxia Liu, Ning Zhou, Songnan Li und 6 weitere

Pacing and Clinical Electrophysiology · 2026

DOI: 10.1111/pace.70143 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, 2026. Verfasst von Song Zuo und 17 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Beijing Anzhen Hospital & Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Pulmonary Veins, Heart Atria, Catheter Ablation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: EnChannel Medical, National Key Research and Development Program of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The cryoballoon catheter is a gold‐standard single‐shot device for pulmonary vein isolation (PVI). Pulsed‐field ablation (PFA) is a tissue‐selective, nonthermal cardiac ablation modality. We assessed the preclinical safety and durability of a novel conformal, balloon‐shaped, single‐shot PFA catheter for PVI and circular atrial lesions.

Methods

A 13 Fr balloon‐shaped PFA catheter (PFBalloon TM , 20 electrodes, 24 mm diameter, EnChannel Medical) was applied using a biphasic waveform of microsecond scale (± 750 V, 4.9 s per application). In 10 swine, superior vena cava (SVC), left superior PV (LSPV), right superior PV (RSPV) and right atrial appendage (RAA) were targeted for isolation. Localization of PFBalloon was evaluated by fluoroscopy and intracardiac echocardiography (ICE). PFA was delivered in a novel tailored configuration (small ring, large ring, or global pulse) to minimize diaphragm stimulation and optimize pulse efficiency. Five swine were assessed at 30 days post‐procedure for lesion durability, gross pathology, and histologic examination, while the remaining five swine were evaluated at 90 days to assess longer term outcomes.

Results

In all 10 swine, PFA resulted in 100% successful acute isolation of the SVC, RSPV, and LSPV using 4.2 ± 0.6, 5.0 ± 1.1, and 4.4 ± 1.8 applications per vein, respectively, and acute isolation of RAA in 9/10 swine using 5.3 ± 2.0 applications. At 30 days post‐procedure, 14 out of 20 targeted sites (70.0%) remained isolated in five pigs. At 90 days, 19 out of 20 sites (95.0%) remained isolated in the remaining five pigs. The overall pulse configurations were 9.0% small ring, 25.4% large ring, and 65.6% global. PFA did not affect phrenic nerve function, with very few microbubbles recorded on ICE. No major complications were observed.

Conclusions

In this preclinical study, a novel conformal, balloon‐shaped catheter designed for single‐shot PVI can create durable isolation without complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary VeinsHeart AtriaCatheter AblationAnimalsSwineIrreversible Electroporation TherapyEquipment Design

Stichwörter der Autor:innen

atrial fibrillationcatheter ablationelectroporationpulmonary veinspulsed fieldsuperior vena cava

Autor:innen und Institutionen

  • Division of Cardiology, Beijing Anzhen Hospital & Capital Medical University, Beijing, China.
  • EnChannel Medical, Inc, Guangzhou, China.

ORCID-Profile: Song Zuo, Caihua Sang, Nian Liu, Changsheng Ma

Förderung

  • EnChannel Medical
  • National Key Research and Development Program of China
  • National Natural Science Foundation of China

Zitieren

APA

Zuo, S., Sang, C., Wang, J., Kong, X., Zhang, J., Gao, M., Dai, W., Zhang, J., Guo, X., Liu, X., Zhou, N., Li, S., Huang, L., Mo, Z., Chen, H., Liu, N., Dong, J., & Ma, C. (2026). Balloon‐Shaped Pulsed Field Ablation for Pulmonary Vein Isolation and Atrial Lesions. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70143

Vancouver

Zuo S, Sang C, Wang J, Kong X, Zhang J, Gao M, et al. Balloon‐Shaped Pulsed Field Ablation for Pulmonary Vein Isolation and Atrial Lesions. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70143

BibTeX
@article{Zuo2026,
  author = {Zuo, Song and Sang, Caihua and Wang, Jue and Kong, Xiangyi and Zhang, Jingrui and Gao, Mingyang and Dai, Wenli and Zhang, Junmeng and Guo, Xueyuan and Liu, Xiaoxia and Zhou, Ning and Li, Songnan and Huang, Long and Mo, Zhidai and Chen, Hao and Liu, Nian and Dong, Jianzeng and Ma, Changsheng},
  title = {Balloon‐Shaped Pulsed Field Ablation for Pulmonary Vein Isolation and Atrial Lesions},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70143}
}
Kostenlos starten →