Vergleichsstudie in der Zeitschrift Pacing and Clinical Electrophysiology, 2026. Verfasst von Kohki Kimura und 5 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Center, Medical Research Institute Kitano Hospital, Osaka City, Osaka, Japan. Hauptthemen laut MEDLINE: Atrial Fibrillation, Heart Atria, Echocardiography, Catheter Ablation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben.
Abstract (Originalsprache)
Background
Pulsed field ablation (PFA) is an emerging, effective therapy for atrial fibrillation (AF). Achieving adequate catheter‐to‐tissue contact is crucial, as poor contact can result in pulmonary vein (PV) reconnection or hemolysis. Intracardiac echocardiography (ICE) enables real‐time visualization of the PFA catheter and PV anatomy. To compare the utility of left atrial (LA) versus right atrial (RA) ICE placement during PFA for AF.
Methods
We retrospectively analyzed 53 consecutive AF patients who underwent index PFA procedures (FARAWAVE, Boston Scientific). Patients were stratified into two groups according to ICE location: RA‐ICE ( n = 20) and LA‐ICE ( n = 33). Procedural characteristics and image quality of catheter and PV anatomy were evaluated.
Results
The total number of PFA applications was higher in the LA‐ICE group than in the RA‐ICE group (45.6 ± 6.8 vs. 35.8 ± 3.4, p < 0.01). Nevertheless, LA‐ICE was associated with a shorter LA dwell time (45.4 ± 13.3 vs. 55.0 ± 17.1 min, p = 0.04) and PV isolation time (19.6 ± 3.9 vs. 25.4 ± 10.5 min, p = 0.01). Visualization of catheter configuration and PV anatomy was significantly better in the LA‐ICE group, particularly for the left inferior and right‐sided PVs ( p < 0.01).
Conclusions
ICE placement in the LA improved visualization of the PFA catheter and PV anatomy, resulting in reduced PV isolation and LA dwell times compared with RA‐ICE.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiovascular Center, Medical Research Institute Kitano Hospital, Osaka City, Osaka, Japan.
ORCID-Profile: Kohki Kimura
Zitieren
APA
Kimura, K., Morita, J., Idoji, M., Hamaguchi, T., Yano, M., & Haruna, T. (2026). Comparing Left Versus Right Atrial Intracardiac Echocardiography in Pulsed Field Ablation for Atrial Fibrillation. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70129
Vancouver
Kimura K, Morita J, Idoji M, Hamaguchi T, Yano M, Haruna T. Comparing Left Versus Right Atrial Intracardiac Echocardiography in Pulsed Field Ablation for Atrial Fibrillation. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70129
BibTeX
@article{Kimura2026,
author = {Kimura, Kohki and Morita, Jun and Idoji, Makoto and Hamaguchi, Toka and Yano, Mariko and Haruna, Tetsuya},
title = {Comparing Left Versus Right Atrial Intracardiac Echocardiography in Pulsed Field Ablation for Atrial Fibrillation},
journal = {Pacing and Clinical Electrophysiology},
year = {2026},
doi = {10.1111/pace.70129}
}
EUVIMED